Technical data
28
CTC EcoZenith i250 
General Information
8.5  Operation data system
This menu displays current temperatures and the 
operational data for your heating system.
Primary flow radiators
The temperature of the primary flow to the house’s 
radiators is shown above the CTC EcoZenith i250 
(42°C). This value will vary during the year according 
to the parameters set and the current outdoor 
temperature.
Return radiators
The return temperature of the radiator water returning to 
EcoZenith is also shown above the CTC EcoZenith i250 
(34°C). This value will vary during operation according to 
the parameters set, the radiator system’s capacity and 
the current outdoor temperature.
The screen shows operational data with the CTC EcoAir 
connected. When the pumps are in operation, the pump icons 
also rotate on screen.
 Svenska  Nederlands  English  Deutsch
 Suomi  Française  Dansk  Norsk
1 2
1 2
  22,2 ºC  21,2 ºC  58 ºC  -5 ºC
1 2
1 2
1 2
1 2
1 2
T ºC
60
40
20
0
-20
16  20  0  4  8 12
00 - 06  22 - 24
00 - 06  22 - 24
00 - 06  22 - 24
00 - 06  22 - 24
00 - 06  23 - 24
00 - 08   23 - 24
00 - 08   22 - 24
06 - 09  18 - 21
07 - 09  -- - --
08 - 09  -- - --
08 -  --  --  - 21
08 -  --  --  - 21
10 - 12   20 - 23
10 - 12   20 - 23
  Room temp.  DHW  Operation  Installer
CTC EcoZenith  Monday 09:35
Night reduction Holiday
Heating circuit 2 (50)
Heating circuit 1
Room temp.
Start menu
Room temperature settings
Selecting DHW comfort
Heating system data
Installer settings menu
Extra
Hot water 
0.0 hours
On
Temperature
Normal
Weekly schedule
DHW
Operation data system
Status HP upper tank
Tank upper°C    49 (58)
Tank lower°C    42 (45)
Electric power kW    0.0+2.5
Current L1/L2/L3 0.0 0.0 0.0
Diff func. Pump / ºC    On 32
Pool ºC Off 22(20)
Operation data EcoZenith
Stored oper data
Heating circuit
Operation data heating
Installer
Time/Language  Settings  Define system  Service
Software display PCB:  20120205
Software HP PCB:  01234
Installer
Installer
Time 21:34
Date 2012-02-05
Settings
Heating circuit 1
Heating circuit 1
Heating circuit 2
Heat pump
Electric heater
Upper tank
Remote control  None
Communication
Solar panels
Diff thermostat function
Pool
Save settings
Load settings
Load factory settings
Max primary flow°C    55
Min primary flow°C    Off
Heating off, out°C    18
Heating off    120
Inclination°C  50
Adjustment°C  0
Room temp reduced°C  -2
 or
Primary flow reduced°C  -3
>>
Define system
Def heating circuit 1
Heating circuit 1
Heating circuit 2
Heat pump
CTC SMS
Cooling
Solar panels
Diff thermostat function  No
Pool (G50, G51, B50)    No
Heating circuit 1    Yes
Room sensor 1    Yes
Type    Wire
Service
Function test
Function test
Alarm log
Factory settings coded
Quick start compressor.
Software update, USB
Write log to USB
Control current sensors
Re-installation
Heating circuit
Heat pump
Valves
Electric heater
Solar
Diff thermostat function
Pool
Total operation time h:  14196
Max primary flow°C:    51
Consumtion kWh    20
Compressor:
 Total Operation time    1540
Stored oper data
Heat pump
Compressor On
Charge pump  On 47%
Brine pump  On
HP in/out°C  35.5 / 42.3
Current L1  4.0
Night reduction heat circ.
Weekly program  Block  NR
Decrease  Sunday 22:00
Increase  Friday 14:00
Decrease  -------- 00:00
Increase  -------- 00:00
Holiday
Holiday period  3 days
Out  Room1 Prim1  Return Room2  Prim2
Settings language
Night reduction heat circ. 1
Weekly program  Day by day  NR
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program  Day by day  DHW
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program DHW
Information
Press the information button to display 
the operational data for the relevant 
item.
Current outdoor temperature 
Shows the current outdoor 
temperature. 
The product uses this value to 
calculate the various operational 
parameters.
1
2
Current indoor temperature 
Shows the current room temperature 
(if a room sensor is selected during 
operation). If two radiator systems 
are installed, the values for both are 
displayed.
The screens also show the incoming and 
outgoing temperatures from the heat 
pump installed.
HP out
At the right of the heat pump (42°C) the heat pump’s 
outgoing temperature is shown.
HP in
At the right of the heat pump (34°C) the heat pump’s 
return temperature is shown.
Brine in (CTC EcoPart only)
At the top left of the EcoPart (2°C) the brine’s current 
temperature from the collector to CTC EcoPart is 
shown.
Brine return (CTC EcoPart only)
The bottom left value (-1 °C) is the return temperature of 
the brine going back into the collector hose. The values 
vary during the year according to the heat source’s 
capacity and the energy drawn out.
1 2
  Dansk  Nederlands  Čeština
  Svenska  Norsk  English
  Eesti  Polski  Slovenščina
  Deutsch  Suomi  Française
Operation data system
Define Cooling
Cooling   No
Common heating/cooling  No
Condense pipe secured  No
Room temp. cooling    25.0
Def heating circuit 1
Heating circuit 1    Yes
Room sensor 1    Yes
Type    Wire
Def heating circuit 1
Heating circuit 1      Yes
Room sensor 1      Yes
Type      Wireless
Action   
Disconnect
Status   
Associated
Level of signal
Battery     85%
Version     x0102
Def CTC SMS
Activate      Yes
Level of signal 
Phone Number 1  +46712345678
Phone Number 2  -----------------
Hardware Version   1 1
Software Version    1 9
Pump H-tank (G46)      Off
Temperatures
H-tank (B6) ºC      32
Test Diff thermostat function
Charge start diff temp ºC
7
Charge stop diff temp ºC
3
Charge temperature °C    60
Sett. Diff termostat function
Holiday
Cooling    20.2 (20.0)
Heating circuit 1    20.2 (20.0)
Room temp.
Night reduction
Op. Heating Circuit
Primary flow1 ºC  33(34)
Return flow ºC  31
Radiator pump  Till
Mixing valve  Open
Delay mixing valve  180
Primary flow 2ºC  33(34)
Radiator pump 2  Från
Mixing valve 2 
Settings language
Settings language
The screen shows operating information with the CTC EcoPart 
connected. When the pumps are in operation, the pump icons 
also rotate on screen.