Technical data

23 CTC EcoZenith i250
General Information
8. Detail Description Menus
All the settings can be configured directly on screen
using the well-structured control panel. The large icons
operate as buttons on the touch display.
Operational and temperature information is also
displayed here. You can easily enter the different menus
to find information on the operation or to set your own
values.
8.1 Start menu
This menu is the system’s start menu. This provides an
overview of the current operation data.
The system returns to this menu if no buttons are
pressed within 10 minutes. All other menus can be
accessed from this menu. NB: Some menus are only
shown if a heat pump is installed.
8.2 Description of icons
Room temp.
Settings for raising or lowering the
temperature indoors and also for scheduling
temperature changes.
DHW
Settings for DHW production.
Operation
This displays current operational data for
both your heating system and heat pump.
Historical operational data is also available.
Installer
This option is used by the installer to
configure the settings and servicing for your
heating system.
1 2
Room temp. Radiator system 1
If radiator system 1 is defined, the current
room temperature is displayed here.
1 2
Room temp. Radiator system 2
If radiator system 2 is defined, the current
room temperature is displayed here.
Tank temperature
This displays the current temperature in the
upper part of the tank.
Outdoor temperature
This displays the current outdoor
temperature.
Home
The Home button takes you back to the Start
menu.
Return
The Return button takes you back to the
previous level.
OK
The OK button is used to mark and confirm
text and options in the menus.
Night reduction
This schedules a temperature reduction at
night if selected.
Holiday
You can use this to reduce the room
temperature permanently, e.g. during holidays
when the house is unoccupied.
Weekly program
This is used to reduce the temperature for a
few days, for instance if you commute every
week.
Stored operation data
This displays historical data.
Time/Language
This is used to set the date, time and the
language you want the menu to be displayed
in.
Settings
The settings for operation of EcoZenith and
the system are usually configured by the
installer.
Define system
The heating system’s structure can be
adjusted/modified using this option.
Service
Advanced settings are configured by the
appropriate technical person.
Svenska Nederlands English Deutsch
Suomi Française Dansk Norsk
1 2
1 2
22,2 ºC 21,2 ºC 58 ºC -5 ºC
1 2
1 2
1 2
1
2
1 2
T ºC
60
40
20
0
-20
16 20 0 4 8 12
00 - 06 22 - 24
00 - 06 22 - 24
00 - 06 22 - 24
00 - 06 22 - 24
00 - 06 23 - 24
00 - 08 23 - 24
00 - 08 22 - 24
06 - 09 18 - 21
07 - 09 -- - --
08 - 09 -- - --
08 - -- -- - 21
08 - -- -- - 21
10 - 12 20 - 23
10 - 12 20 - 23
Room temp. DHW Operation Installer
CTC EcoZenith Monday 09:35
Night reduction Holiday
Heating circuit 2 (50)
Heating circuit 1
Room temp.
Start menu
Room temperature settings
Selecting DHW comfort
Heating system data
Installer settings menu
Extra
Hot water
0.0 hours
On
Temperature
Normal
Weekly schedule
DHW
Operation data system
Status HP upper tank
Tank upper°C 49 (58)
Tank lower°C 42 (45)
Electric power kW 0.0+2.5
Current L1/L2/L3 0.0 0.0 0.0
Diff func. Pump / ºC On 32
Pool ºC Off 22(20)
Operation data EcoZenith
Stored oper data
Heating circuit
Operation data heating
Installer
Time/Language Settings Define system Service
Software display PCB: 20120205
Software HP PCB: 01234
Installer
Installer
Time 21:34
Date 2012-02-05
Settings
Heating circuit 1
Heating circuit 1
Heating circuit 2
Heat pump
Electric heater
Upper tank
Remote control None
Communication
Solar panels
Diff thermostat function
Pool
Save settings
Load settings
Load factory settings
Max primary flow°C 55
Min primary flow°C Off
Heating off, out°C 18
Heating off 120
Inclination°C 50
Adjustment°C 0
Room temp reduced°C -2
or
Primary flow reduced°C -3
>>
Define system
Def heating circuit 1
Heating circuit 1
Heating circuit 2
Heat pump
CTC SMS
Cooling
Solar panels
Diff thermostat function No
Pool (G50, G51, B50) No
Heating circuit 1 Yes
Room sensor 1 Yes
Type Wire
Service
Function test
Function test
Alarm log
Factory settings coded
Quick start compressor.
Software update, USB
Write log to USB
Control current sensors
Re-installation
Heating circuit
Heat pump
Valves
Electric heater
Solar
Diff thermostat function
Pool
Total operation time h: 14196
Max primary flow°C: 51
Consumtion kWh 20
Compressor:
Total Operation time 1540
Stored oper data
Heat pump
Compressor On
Charge pump On 47%
Brine pump On
HP in/out°C 35.5 / 42.3
Current L1 4.0
Night reduction heat circ.
Weekly program Block NR
Decrease Sunday 22:00
Increase Friday 14:00
Decrease -------- 00:00
Increase -------- 00:00
Holiday
Holiday period 3 days
Out Room1 Prim1 Return Room2 Prim2
Settings language
Night reduction heat circ. 1
Weekly program Day by day NR
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program Day by day DHW
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program DHW