Specifications
Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 80 2012.12.10
192 GET RESPONSE
214 UPDATE BINARY
220 UPDATE RECORD
242 STATUS
All other values are reserved; refer GSM 11.11.
<fileId> Integer type; this is the identifier for an elementary data file on
SIM. Mandatory for every Command except STATUS
<P1>,<P2>,<P3> Integer type, range 0 – 255
Parameters to be passed on by the ME to the SIM; refer GSM
11.11.
<data> Information which shall be written to the SIM (hex-decimal
character format)
<sw1>,<sw2> Integer type, range 0 - 255
Status information from the SIM about the execution of the
actual Command. These parameters are delivered to the TE in
both cases, on successful or failed execution of the Command;
refer GSM 11.11.
<response> Response of a successful completion of the Command
previously issued (hexadecimal character format)
Reference
GSM 07.07
GSM 11.11
Note
3.2.35 AT+CSQ Signal Quality Report
AT+CSQ Signal Quality Report
Test Command
AT+CSQ=?
Response
+CSQ: (list of supported <rssi>s),(list of supported <ber>s)
OK
Response
+CSQ: <rssi>,<ber>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Execution Command returns received signal strength indication <rssi>
and channel bit error rate <ber> from the ME. Test Command returns
values supported by the TA.
Execution
Command
AT+CSQ
Parameters
<rssi>
0 -115 dBm or less
1 -111 dBm