Specifications

Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 77 2012.12.10
See Write Command
Response
TA controls whether or not the extended format of incoming call
indication is used.
OK
Parameter
<mode> 0 Disable extended format
1 Enable extended format
Omitted Use previous value
Unsolicited Result Code
When enabled, an incoming call is indicated to the TE with unsolicited
result code +CRING: <type> instead of the normal RING.
Write Command
AT+CRC=[<mod
e>]
Parameter
<type> ASYNC Asynchronous transparent
SYNC Synchronous transparent
REL ASYNC Asynchronous non-transparent
REL SYNC Synchronous non-transparent
FAX Facsimile
VOICE Voice
Reference
GSM 07.07 [13]
Note
3.2.32 AT+CREG Network Registration
AT+CREG Network Registration
Response
+CREG: (list of supported <n>s)
OK
Test Command
AT+CREG=?
Parameter
See Write Command
Read Command
AT+CREG?
Response
TA returns the status of result code presentation and an integer <stat>
which shows whether the network has currently indicated the registration
of the ME. Location information elements <lac> and <ci> are returned
only when <n>=2 and ME is registered in the network.
+CREG: <n>,<stat>[,<lac>,<ci>]
OK
If error is related to ME functionality:
+CME ERROR: <err>