Specifications

Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 52 2012.12.10
Response
+CCWA: <n>
OK
Read Command
AT+CCWA?
Parameter
See Write Command
Response
TA controls the Call Waiting supplementary service. Activation,
deactivation and status query are supported.
If <mode>2 and Command successful
OK
If <mode>=2 and Command successful
+CCWA: <status>,<class1>[<CR><LF>+CCWA:
<status>,<class2>[...]]
OK
ERROR
If error is related to ME functionality:
+CME ERROR: <err>
Note: <status>=0 should be returned only if service is not active for any
<class> i.e. +CCWA: 0, 7 will be returned in this case.
When mode=2, all active call waiting classes will be reported. In this mode
the Command is aborted by pressing any key.
Parameters
<n> 0 Disable presentation of an unsolicited result code
1 Enable presentation of an unsolicited result code
<mode> When <mode> parameter not given, network is not
interrogated
0 Disable
1 Enable
2 Query status
<class> Is a sum of integers each representing a class of information
1 Voice (telephony)
2 Data (refers to all bearer services; with <mode>=2 this
may refer only to some bearer service if TA does not
support values 16, 32, 64 and 128)
4 Fax (facsimile services)
7 Default(1+2+4)
<status> 0 Not active
1 Enable
Write Command
AT+CCWA=<n>[,
<mode>[,<class>]]
Unsolicited Result Code
RING