Specifications
Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 25 2012.12.10
during some states of connection establishment such as handshaking.
If error is related to ME functionality
+CME ERROR: <err>
If no dial tone and (parameter setting ATX2 or ATX4)
NO DIALTONE
If busy and (parameter setting ATX3 or ATX4)
BUSY
If a connection cannot be established
NO CARRIER
If the remote station does not answer
NO ANSWER
If connection successful and non-voice call.
CONNECT<text> TA switches to data mode.
Note: <text> output only if ATX<value> parameter setting with the
<value> >0
When TA returns to Command mode after call release
OK
If successfully connected and voice call
OK
Reference
V.25ter
Note
z See ATX Command for setting result code and call monitoring
parameters.
z Return the numbers and symbols which ATD supports if there is no
last dialing context.
2.2.7 ATE Set Command Echo Mode
ATE Set Command Echo Mode
Response
This setting determines whether or not the TA echoes characters received
from TE during Command state.
OK
Execution
Command
ATE<value>
Parameter
<value> 0 Echo mode off
1 Echo mode on