Specifications
Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 227 2012.12.10
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+FTPPW=<v
alue>
Parameter
<value> Alphanumeric ASCII text string up to 49 characters.
Reference
Note
11.2.10 AT+FTPGETNAME Set Download File Name
AT+FTPGETNAME Set Download File Name
Test Command
AT+FTPGETNA
ME=?
Response
OK
Response
+FTPGETNAME: <value>
OK
Read Command
AT+FTPGETNA
ME?
Parameter
See Write Command
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+FTPGETNA
ME=<value>
Parameter
<value> Alphanumeric ASCII text string up to 99 characters
Reference
Note
11.2.11 AT+FTPGETPATH Set Download File Path
AT+FTPGETPATH Set Download File Path
Test Command
AT+FTPGETPA
TH=?
Response
OK
Read Command
AT+FTPGETPA
TH?
Response
+FTPGETPATH: <value>