Specifications
Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 205 2012.12.10
Parameters
See Write Command
Response
+CIPUDPMODE: <mode> [,<IP address>,<Port>]
OK
Read Command
AT+CIPUDPMOD
E?
Parameters
See Write Command
Response
OK
ERROR
Write Command
AT+CIPUDPMOD
E=<mode>[,<IP
address>,<Port>]
Parameters
<mode> 0 UDP Normal Mode
1 UDP Extended Mode
2 Set UDP address to be sent
<IP address> A string parameter (string should be included in quotation
marks) which indicates remote IP address
<port> Remote port
Reference
Note
This Command is used to set UDP extended mode, for single IP connection
(+CIPMUX=0)
8.2.26 AT+CIPRXGET Get Data from Network Manually
AT+CIPRXGET Get Data from Network Manually
Response
If single IP connection (+CIPMUX=0)
+CIPRXGET: (list of supported <mode>s),(list of supported <reqlength>)
OK
If multi IP connection (+CIPMUX=1)
+CIPRXGET: (list of supported <mode>s), (list of supported <id>s), (list
of supported <reqlength>)
OK
Test Command
AT+CIPRXGET=
?
Parameters
See Write Command
Read Command Response