Specifications
Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 202 2012.12.10
>,<timer>]
Parameters
<mode>
0 Not set detect PDP
1 Set detect PDP
<interval>
1<interval<=180(s)
<timer>
1<timer<=10
Reference
Note
If "+PDP: DEACT" urc is reported because of module not attaching to gprs
for a certain time or other reasons, user still needs to execute
"AT+CIPSHUT" command makes PDP context come back to original state.
8.2.22 AT+CIPMODE Select TCPIP Application Mode
AT+CIPMODE Select TCPIP Application Mode
Response
+CIPMODE: (0-NORMAL MODE,1-TRANSPARENT MODE)
OK
Test Command
AT+CIPMODE=
?
Parameter
See Write Command
Response
+CIPMODE: <mode>
OK
Read Command
AT+CIPMODE?
Parameter
See Write Command
Response
OK
ERROR
Write Command
AT+CIPMODE=
<mode>
Parameter
<mode> 0 Normal mode
1 Transparent mode
Reference
Note