Specifications

Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 176 2012.12.10
7.2.5 AT+CGACT PDP Context Activate or Deactivate
AT+CGACT PDP Context Activate or Deactivate
Response
+CGACT: (list of supported <state>s)
OK
Test Command
AT+CGACT=?
Parameters
See Write Command
Response
+CGACT: <cid>,<state>[<CR><LF>+CGACT: <cid>,<state>…]
OK
Read Command
AT+CGACT?
Parameters
See Write Command
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CGACT=[<s
tate> [,<cid>]]
Parameters
<state> Indicates the state of PDP context activation
0 deactivated
1 activated
Other values are reserved and will result in an ERROR
response to the Write Command.
<cid> A numeric parameter which specifies a particular PDP context
definition (see +CGDCONT Command)
1..3 PDP Context Identifier, cid 3 is reserved and is always
defined, it cannot be changed by user.
Reference
Note
z This command is used to test PDPs with network simulators.
Successful activation of PDP on real network is not guaranteed.
z Refer to AT+CGDATA clarification for more information.
7.2.6 AT+CGDATA Enter Data State
AT+CGDATA Enter Data State
Test Command
AT+CGDATA=?
Response
+CGDATA: list of supported <L2P>s
OK