Specifications

Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 140 2012.12.10
marks) -The alpha-string to write to the SIM
Reference Note
6.2.20 AT+CBAND Get and Set Mobile Operation Band
AT+CBAND Get and Set Mobile Operation Band
Response
+CBAND: (list of supported <op_band>s)
OK
Test Command
AT+CBAND=?
Parameter
See Write Command
Response
+CBAND: <op_band>[,<ALL_BAND>]
OK
Read Command
AT+CBAND?
Parameter
See Write Command
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CBAND=<o
p_band>
Parameter
<op_band> A string parameter which indicate the operation band.
And the following strings should be included in quotation
marks.
EGSM_MODE
PGSM_MODE
DCS_MODE
GSM850_MODE
PCS_MODE
EGSM_DCS_MODE
GSM850_PCS_MODE
EGSM_PCS_MODE
ALL_BAND
Reference Note
Radio settings are stored in non-volatile memory.