Specifications
Smart Machine Smart Decision
SIM900_AT Commands Manual_V1.07 129 2012.12.10
3 +4.5 dB
4 +6.0 dB
5 +7.5 dB
6 +9.0 dB
7 +10.5 dB
8 +12.0 dB
9 +13.5 dB
10 +15.0 dB
11 +16.5 dB
12 +18.0 dB
13 +19.5 dB
14 +21.0 dB
15 +22.5 dB
Reference Note
z Please refer to actual model for channel number.
z <gainleveln> value is related to <channel> specific.
6.2.5 AT+CALA Set Alarm Time
AT+CALA Set Alarm Time
Response
+CALA: ("yy/mm/dd,hh:mm:ss","hh:mm:ss"),(1-5),(0-7)
OK
If error is related to ME functionality:
+CME ERROR: <err>
Test Command
AT+CALA=?
Parameters
See Write Command
Response
[+CALA: <time>,<n1>[,<recurr>]
[<CR><LF> +CALA: <time>,<n2>[,<recurr>] …]]
OK
If error is related to ME functionality:
+CME ERROR: <err>
Read Command
AT+CALA?
Parameters
See Write Command
Write Command
AT+CALA=<tim
e>[,<n>
[,<recurr>]]
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>