User`s guide

76 VEREX Director V4.73 User's Guide 21-0381E v4.7.3
Introduction to Status & Control
The Status and Control Feature
VEREX Director can monitor the status of most
system, area, and device a spects, and al lows
controlling the system on an area-by-area
basis, or for individual doors or input points.
Also See ( V4.0):
+ Visual Status and Control (Maps and Cameras)
+ To Connect: "New Installation? Try the Wizard
The status for individual ite ms at specific site
can be checked manually, as desired. As well,
the status toolbar allow s m onitoring a de sired
account for various items (sirens, fire alarms,
other alarms, and trouble conditions), and
provides a q uick way to v iew the details for
each item.
Items to be available under Control & Status depend on
the authorities associated with the user
ID and PIN
entered when logging into "Control & Status". If you
were not asked to enter a user ID and PIN, then one
has been set up for automatic entry in your operator
settings. For details, refer to the section on
"Operators".
Status monitoring (either manually, or through the
status toolbar), requires that the VEREX Director
system be connected with the specific panel(s), and the
specific devices must be communicating.
If an item is listed as 'Off-Line', this typically indicates
either a communications problem, or a set-up error
(such as an incorrect module/POD serial number).
If all items on a screen are grey in colour, this generally
means that you are either not connected with the
specific panel, or the applicable module is 'off-line' (not
communicating).
Items changed through 'Control & Status' (such as
unlocking a door, or locking-out cards, etc.) remain in
effect until changed by another person or by a
scheduled Configuration setting.
Connecting to the Associated Panel(s),
An Overview:
1) See if you're already connected by
checking the status bar at the bottom
of the monitoring window.
Multi-Account systems: Ensure your desired
account is selected (click [Account Folders]
in the tree, and then double-click the specific
account).
2) If not connected, check to ensure the
communication software is running
on the specific PCs.
Detail: If the LCD/Telephone icon on the
Windows taskbar is black-and-white (colour =
running), start the communications service by
right-clicking the icon, and selecting "Start
Communications".
Related Topic
: Serial Port / Modem Setup
(Communications Manager)
3) Selec t Communications from your
MyTools bar, or
click
[Communications] in the 'tree', and
select Pending/OnLine.
4) Click the [+] at the bottom of the
form, or right-click the form, and
select Add New from the pop-up
menu. Then, select the desired
panel(s) (double-click to select), and
set "Action" to "Normal", and
"Frequency" to "Stay Connected" (9).
(Click OK when finished.)
5) Check that the connection is made, and
watch for the panel updates to occur.
(Click the 'Panel Group', and look for the status on
the right side of the screen.)
Note: Control & Status features will be available after
the panel updates have finished (look for a connection
state of 'Connected' and 'Idle State'.)
Also See (Related Topics):
+ "Panel Communications and Updates"
Checking Status & Controlling Items