User`s guide
21-0381E v4.7.3
Welcome Report
Control Admin S ys Config Tech-Ref
61
___________________________________________
Input-Point Commands
(After right-clicking a Sensor)
Also See: "Common Commands", previous/above.
-------------------------------------------------------------------------
- Bypass / Remove Bypass: "Bypass" allows
arming an area with a tripped or faulty input
point (sensor). "Remove Bypass" allows
monitoring the input point again (for a sensor
that is "OK").
____________________________________________
Output-Point Commands
(After right-clicking an Output/Device)
Also See: "Common Commands", previous/above.
--------------------------------------------------------------------------
Tips
: First, select "Manual Output Control".
Additional parameters appear when applicable
(duration, etc.).
- Normal: No manual control (i.e., return to
normal operation);
- Always: Allows setting the output as On
or Off
continuously (until manual control is removed);
- Momentary: Allows setting the output to
pulse/toggle once. Additional selections will
appear for: • Whether it is to be triggered On
(high), or Off
(Low); • The state it will be left in
afterwards (Off
, On, or Normal); • How long the
relay will remain triggered (1 second to 1 week).
- Duty Cycle (1 sec. On/1 sec. off): The output
will be pulsed on and off continuously for a
selected duration (1 second to 1 week).
___________________________________________
Elevator Commands
(After right-clicking an Elevator)
Also See: "Common Commands", previous/above.
-------------------------------------------------------------------------
- Secure / Desecure: This allows applying or
removing controlled-access for all floors as
accessed from the specific elevator (lift).
(Secure: An access card or token provides access to
specific floors; • Desecure
: Anyone can access any
floor without a card or token.
Controlling a Floor (as accessed from all cabs): Refer
to "Checking Status or Controlling Floors"