User`s guide

21-0381E v4.7.3
Welcome Report Control Admin
Sys Config Tech-Ref
285
System Tone if Module Fail
Fallback sonalert (at control panel) if Module
Bus fails. Provides 1 sec. output every 8 sec.
And activates if there is no operational
keypad in an area with programmed
keypads.
System Grou nd Start
Ground Start (can only be used on B004 -
main panel output 4)
System F ully On
When system is FULLY ON
System Par tially On
When system is PARTIALLY ON (Partially or
Fully On for Europe Version)
System Fully Off
When system is FULLY OFF
System In Alarm
When system is IN ALARM - resets when
point(s) restore (includes pseudos &
tampers)
System Siren
Follows ALARM & FIRE siren (steady)
System Siren Fire (1 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 1 sec on/off for FIRE
per Keypad Tone. Exception
: If selected for
the siren output (#3 on main panel), this
enables UL fire-cadence: ½ sec on/off three
times, 1sec pause, and repeats.
System Siren Fire (2 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 2 sec on/off for FIRE
System Digital Trouble
Phone line trouble (follows report delay or
line failure)
System Was In Alarm
System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for system
trouble (clears when alarmed areas are
turned off then back on again)
System B ypassed
When there is a point BYPASSED
somewhere in the system
System F ire
When any ‘FIRE’ point is in alarm
System Hold-Up
When any ‘HOLD UP’ point is in alarm
System Aux iliary Alert
When any ‘Aux Alert' point is in alarm
System Vault
When any ‘VAULT / SAFE’ type point is in
alarm
System B urglary
When any ‘'Burglary' point is in alarm.
Delayed burglary for European Version.
System Supervisor y
When any ‘Supervisory' point is in alarm.
System Pseudo
When any 'Pseudo' condition is in effect.
System S ystem Trouble
Pseudo 1 – System Trouble / All type tamper
for European Version.
System Batter y Trouble
Pseudo 2 – Battery Trouble
System AC Failure
Pseudo 3 – AC (Mains) Trouble
System Phone Line Trouble
Pseudo 4 – Phone Trouble
System Report Delay
Pseudo 5 – Report Delay
System Time Lost
Pseudo 6 – Time Lost
System Time Changed
Pseudo 7 – Time Change
System Program Changed
Pseudo 8 – Program Change
System Program Error
Pseudo 9 – Program Error
System F use Failure
Pseudo 10 – Fuse Failure
System Pod Trouble
Pseudo 11 – Module Trouble
Programmable Output Functions
Failed to Close: Area schedule expired, & no one armed the system; In Window: Schedule active; Out
Window: Schedule expired; Pseudo: Internally monitored conditions (Ref: Config. ÖSystem ÖEquipment);
Version "E"
: This indicates conditions pertaining to European monitoring requirements (requires Director V4.2).
System (events pertaining to the specific main/system panel):