User`s guide
21-0381E v4.7.3
Welcome Report Control Admin
Sys Config Tech-Ref
277
be ‘toggled’ off at a keypad by
pressing ƒ5);
Exception: For keyswitch operation, see
the previous "Keyswitch" note.
- Pre-Alarm Warning: For associated
input-points, alarm transmission (to the
central station) will be delayed as per
the "Pre-Alarm Delay" setting (for the
specific 'area'). During the delay,
keypad sonalert(s) will be sounded,
giving an authorized user time to
"Silence" the alarm at a keypad.
(Selecting "Verify User" will cancel the
alarm transmission.)
Siren Time: To allow a pre-alarm warning
to occur, the siren time for the panel must be greater
than 30 seconds. (Siren Time appears under:
Configuration, ÖSystem, ÖStandard )
For details on setting the "Pre-alarm Delay" time, refer
to "Areas and Related Settings".
To assign an area to be monitored by a specific
keypad, refer to "Expansion Modules".
For Command Points
: This selection does not apply
to command points (do not select 'Pre-Alarm Warning'
for command points).
Transmit
- Off / Stay / On: The (applicable area’s) arming
levels for which an alarm message will be
transmitted to the monitoring station whenever
the point is triggered;
For Command Points: Other than issuing the specific
action, command-points are monitored only for
'Tamper' conditions.
Sonalert
- Off / Stay / On: The (applicable area’s) arming
levels for which keypad sonalerts will be
sounded for 1 second when the point is
triggered;
Siren
- Off / Stay / On: The (applicable area’s) arming
levels for which siren outputs will be sounded
when the point is triggered. (The “Siren Time” is
set through the System screen.)
For Command Points: Other than issuing the specific
action, command-points are monitored only for
'Tamper' conditions. So, the Transmit, Sonalert, and
Siren selections will take effect only for tamper
conditions.
Configuration ÖCustom Point Types