User`s guide
274 VEREX Director V4.73 User's Guide 21-0381E v4.7.3
Input Points—Pre-Defined Sensor Types
Burglary Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx
Off
Tx
Stay
Tx
On
Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Entry Door Perimtr Door (area 1) Burg --
9
--
9 9
--
9 9
--
9 9
Entry Route 12hr E/E Route Burg
9
-- --
9
--
9
-- --
9
Perimeter Perimeter Immed Burg
9 9
--
9 9
--
9 9
--
9 9
Interior Motion 12hr Immed Burg
9
-- --
9
-- --
9
-- --
9
FAP - Motion 12hr FAP Burg
9
-- --
9
-- --
9
-- --
9
Day Warning 24hr Immed Burg
9
-- --
9 9 9 9
-- --
9
24hr Burglary 24hr Immed Burg
9
--
9 9 9 9 9 9 9 9 9
Life/Safety Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx Off Tx
Stay
Tx On Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Fire - A 24hr Immediate Fire-A
9 9 9 9 9 9 9 9 9
Fire 24hr 15s delay Fire
9 9 9 9 9 9 9 9 9
Fire 24hr Immediate Fire
9 9 9 9 9 9 9 9 9
Hold-up 24hr Immediate holdup
9 9 9
Aux Alert 24hr Immediate Emerg
9 9 9 9 9 9 9 9 9
Supervisory Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx Off Tx
Stay
Tx On Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Supervisory 24hr Immediate Spvsr
9
9 9 9 9 9 9
Local Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx
Off
Tx
Stay
Tx
On
Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Local - 24hr 24hr Immed Burg
9
9 9 9 9 9 9
Local-Stay&On Perimeter Immed Burg
9 9
9 9
9 9
Local-
Stay2 & ON
Perimeters Immed Burg
9 9
9
9
Local -
ON only
12 hr Immed Burg
9 9
9
9
Legend:
• The 'Class' setting determines the type of alarm message to be transmitted;
• Bypass means whether or not the input point will be bypassable;
• Chime pertains to whether or not the triggering of the input will cause audible tones at keypads in the
area (normally used with Entry points/routes to let you know that someone has entered);
• Tx Off, Stay, and On pertain to the arming levels for which activation of the input point will cause an
alarm to be transmitted to the monitoring station;
• Sonlrt Off, Stay, and On pertain to the arming levels for which activation of the input point will cause
keypad 'sonalerts' in the area to be sounded for one second.
• Siren Off, Stay, and On pertain to the arming levels for which activation of the input point will cause
siren outputs in the area to be sounded.