Pick-Lists (Bottom of the
Form)
-Panel Group & Panel references (optional;
bottom of the form): This is where you
select a specific panel-group and panel in a
multi-panel system where the 'tree' is not
set to show items on a panel-by-panel
basis. For more information on this feature,
refer to "Other Desktop Choices".
- Input Point (bottom of form): This is
where you select an input-point to view
or edit. This area shows a reference
number assigned by the system, and the name
of the selected 'input', once defined;
The input-point numbers are assigned by the system
when a module (POD) that supports input points is set
up. The number assigned to each input-point is based
on the module installation order, and the number of
input-points supported by (reserved for) each module.
Tip: The "Module" and "Range" settings show the
device associated with the input-point, and the range
of input-points for that device.
"Offset" values for each panel determine whether
multi-panel sites will have consecutive versus
repeating input-point-numbers. For details, refer to
the "Display Offsets" value under "System Panels and
Displayed Item-Numbers".
Top of the Form
- Name: A suitable description for the input point
indicating its location and/or usage, etc.
Standard
- LCD Name: A shorter version of the name to be
displayed at LCD keypads. This is assigned
automatically, and can also be changed if
desired (max. 12 chars., plain text).
Command Points: For input points set as "Point Type:
Custom Type: Command Point", the LCD name will
be replaced with point-command data, and will not be
editable.
- Module: This is "Panel" (a system panel) or the
module/POD associated with the specific input
point number.
-------------------------
- Range: This is the total range of input point
numbers associated with the specific
module/POD (as defined by the software when
each module is set up).
Tip: The number in brackets, such as "(1)", pertains
to the location of the physical input-point connection
on the specific module.
- Point Type: The type of sensor and/or the type
of monitoring to be used with this point (E/E
door, PIR, etc.), and to identify the input points
that are on the perimeter of an area. The
selections include many pre-defined types, plus
‘custom types 80-99’ that can be set up
manually. Tip: Pause the mouse cursor over a
point-type in the list to view its associated
characteristics.
To set up a garage/extended-delay input, or other
custom type of sensor, refer to "Input Points--Custom
Point Types".
EE Door
: This pertains to entry/exit doors that are
monitored by the system, but not
electronically
controlled for personnel access. To set up an access-
controlled door (and its dedicated inputs), refer to
"Doors, Readers, and Related Settings".
Configuration ÖInput Points