251
-------------------------
Then, issue a "Send to Panel"
communications session to
transfer all settings to the
associated panel.
For details, refer to "Panel
Communications and Updates".
Pick-Lists (bottom of the
Form)
-Panel Group & Panel references
(optional): This is where you select
a specific panel-group and panel in
a multi-panel system where the
'tree' is not
set to show items on a
panel-by-panel basis. For more
information on this feature, refer to
"Other Desktop Choices".
- Suite: This is where you select a suite-security
keypad to view or edit. This area shows a
reference number assigned by the system, and
the name of the 'suite' or keypad, once defined;
"Offset" values for each panel determine whether
multi-panel sites will have consecutive versus
repeating keypad ID-numbers. For details, refer to the
"Display Offsets" value under "System Panels and
Displayed Item-Numbers".
Top of the Form
- Name: A suitable name/location to be
associated with the suite or keypad (such as the
suite number and/or occupant);
Standard
- Serial Number: The actual serial number of the
suite-security keypad. Tip: The serial number
is typically hand-written (5 digits) on a small
sticker on the circuit board.
- Keypad Type: Two-zone (compact) versus 8-
zone (full-featured);
Director ≥V4.4: Newer suite keypad models support 4
monitored sensors (inputs), one programmable output,
and 3 'panic keys'. Uses custom input circuit types.
Future
: A reader may be built-in, or supported
externally.
- First User Access: Users with access to suite
keypads are reserved in blocks of 8 (such as 1
st
suite: users 1-8, 2
nd
suite: users 9-16, etc.).
This value is the lowest user-ID to pertain to this
suite/keypad. This number must be a multiple of
8, plus 1.
To set up the person associated with each user-ID,
refer to "Users (Entrants / Panel Users)".
Tip: If desired, you can automatically reset the users
for all defined keypads (or up to a desired one) to the
default of consecutive
blocks of 8: Select the highest
numbered keypad to be affected. Then, right-click
anywhere on its form, and select Auto Fill User
Offset. When asked to confirm, select Yes.
-------------------------
- Last Communicated: During each
communications session, the software will check
the keypad type, and display it here.
- User Access Range: This shows the range of
user ID numbers to pertain to this suite/keypad,
based on the 'First User Access' value (prev.).
-------------------------
- Floor: The is the floor associated with the
suite/facility (or the lower of two for suites that can be
accessed from two floors)
.
- Additional Floor: Select this if the suite/facility
can be accessed from two floors.
- LCD Name: A shorter version of the name to be
displayed at LCD keypads. This is assigned
automatically, and can also be changed if
desired (max. 12 chars., plain text).
- Digital Account ID: Future Use. For central
monitoring.
- Report Mode: Future Use. For central
monitoring.
Configuration ÖSuite Security