242 VEREX Director V4.73 User's Guide 21-0381E v4.7.3
Activity Monitoring and Auto-
Arming
General Operation
Activity monitoring can be set to transmit an
alarm and/or arm areas automatically when
activity is not detected for a specific length of
time. Per the operator's selections, this
automated arming can:
+ Be triggered by "No Activity", and/or; "User
Count ≤ a preset minimum value" remaining in
effect for a set duration (timeout value).
+ Pertain to inputs set as "Activity Monitor"
custom points, sensors on the entry/exit route,
and/or door openings.
+ Arm to ON or Stay
+ Occur with or without an optional configurable
delay time before arming
(to allow users additional time to either trigger
activity, or leave the area)
+ Can operate either any time, or only outside of
an Arm/Disarm schedule selected on the
"Scheduling" tab for the specific area (if
applicable).
Tip
: The arming level(s) for which an Activity
Monitor input point will monitor activity is
determined by the "Level" setting for the
Custom Point Type (Off, Off/Stay, or "Always").
(The rest of the time, the point(s) will be treated
as a standard point (Burg., supervisory, etc.--
per selections for the custom point type).
Locator: Config., ÖCustom Point Types,
Ö("Preprocess: Activity Monitor"), Ö"Level"
and "Class".
Steps
1) Define a "Custom Point Type", being sure
to select: "Preprocess: Activity Monitor",
and other settings as desired. Locator:
Configuration, ÖCustom Point Types.
2) Set up any activity monitoring input
points, being sure to assign your custom
point type to each one.
Locator: Configuration, ÖInput Points.
3) For each applicable area, make
selections as desired for the "Activity"
and "Auto Arm" screens.
Locator: Configuration, ÖAreas,
Ö"Activity " and "Auto Arm ".