User`s guide
21-0381E v4.7.3
Welcome Report Control Admin
Sys Config Tech-Ref
235
Pick-Lists (bottom of the form)
-Panel Group & Panel references (optional):
This is where you select a specific panel-
group and panel in a multi-panel system
where the 'tree' is not
set to show items on
a panel-by-panel basis. For more
information on this feature, refer to "Other
Desktop Choices".
- Equipment: This is where you select
an internally monitored item to view or
edit. This area shows a reference
number assigned by the system, plus
a description of the item;
On This Form
- Name: The event / alarm condition
being configured (these names are set
by the system, and cannot be
changed).
- Preprocess: The duration that the
condition must remain
in effect before
an alarm will be audited.
Transmit
- Off / Stay / On: The (applicable area’s) arming
levels for which a message of the event will be
transmitted to the monitoring station;
Sonalert
- Off / Stay / On: The (applicable area’s) arming
levels for which keypad sonalerts will be
sounded for 1 second when the alarm occurs;
Siren
- Off / Stay / On: The (applicable area’s) arming
levels for which siren outputs will be sounded
when the alarm occurs. (The “Siren Time” is set
through the System screen.) For details, refer
to "System Security Settings for a Panel".