Card Version (Version-Number)
This feature requires V3.2 panel firmware
and
V1.5 door/elevator controller module
firmware. For an additional setting, refer to
"AutoUpdate Card Version", under
Special (to follow).
- Version Required: This
enables/disables version number
checking (allows fixed-ID cards to be
re-issued if lost or stolen).
- Position: The starting position of the
version number (1-40).
- Length: The length of the version
number (MS: 1-2; W: 1-8).
Card ID
- Position: The starting position of card
ID number (1-40);
- Length: The length of card ID number (MS: 4-9;
W: 1-32).
32-Bit Cards: Supported with panel firmware V3.2,
and door/elevator controller module firmware
V1.5
(prev. 20 bit / 6 digits).
V3.2 panels: MaxID=999999999; V3.31 Panels:
MaxID=4
294 967 295.
- Bits per Card: The length of the card data in
bits (Wiegand), or characters (magnetic stripe).
This can be up to 40.
- Bits per Character
(magstripe only): The number
of bits used to identify each character of data on
a magstripe card (future use; fixed as 4).
Odd Parity
These settings pertain to odd-parity checking, which
helps to identify card 'misreads'.
- Position: The position of the odd-parity
'checksum' (1-40);
- Start: The starting position of the data being
checked for odd-parity (1-40);
- Length: The number of digits being checked for
odd-parity (1-40).
Even Parity
These settings pertain to even-parity checking, which
helps to identify card 'misreads'.
- Position: The position of the even-parity
'checksum' (1-40);
- Start: The starting position of the data being
checked for even-parity (1-40);
- Length: The number of digits being checked for
even-parity (1-40).
Special (Miscellaneous Items)
- Door Fallback Mode: Cards to be granted
access if the door controller module is unable
to communicate with the main panel
database:
None: No cards/tokens accepted;
Valid Token Format: All readable
cards/tokens accepted;
Valid Site Code: All cards/tokens with the
correct site code will be granted access;
10 Fall-back Users: Only the users who are
assigned as 'FallBack Users'. For details,
refer to "Fall-Back Users...".
- Unlock All Doors On Fire Alarm: If selected,
all doors in all areas associated with this
panel will automatically unlock when a fire
alarm is detected by this panel.
- AutoUpdate Card Version: For fixed-ID
cards with a version number, this sets how re-
issued cards are to be handled.
; = Grant access to a card with higher version
number, and update the version number for the
specific user automatically;
= Only cards that match the version number for
each user will be granted access (must update
manually when a card is re-issued).
To set the initial/actual version number for specific
card(s), refer to the section on "Users".
For additional related settings, refer to "Card Version"
(previous). Panel Version
: This feature requires V3.2
panel firmware.
Configuration ÖSystem ÖAccess
Note: For a system set for intrusion-only (under Account Information),
the "Access" tab will appear as "Token Format".