User`s guide

168 VEREX Director V4.73 User's Guide 21-0381E v4.7.3
Fall-Back Users for a Panel
At each pa nel, various c ard-access
modes are supported for use in the
event of a communications failure
(i.e. a door or elevator controller
module being unable to com municate
with the s ystem panel). Th is feature
(door fallback mode), in cludes a
selection for letting up to 1 0 specific
users gain e ntry during the 'comms
failure'. These users are know n as
"Fall-Back Users".
Elevator (Lift) Cabs: This feature is also
supported for individual elevator (lift) cabs.
See: Elevators (Lifts) and Associated
Readers
Ensure 'Fall-Back User' Mode is
Enabled
How to Get Here
Multi-Account Systems: First select [Account Folders]
in the 'tree', and locate and double-click the desired
account.
MyTools Bar : System Access
In the Tree
: Configuration (click the "+") ,
ÖSystem, ÖAccess
(Under the specific panel
group and panel--if listed in the 'tree'.)
Related Topic: "Other Desktop Choices"
Steps:
Ensure you are in "Forms" view (click the Form
/ Grid toolbar-button if needed).
Select the " Special" tab, and then e nsure
Door Fallback mode is set as "10 fallback
users". When finished, click [Save].
"Fallback User" will now appear at the bottom of the
'Configuration' area of the tree (for the specific panel).
To set the "Fallback Mode" for an elevator (lift) cab,
refer to "Elevators (Lifts) and Associated Readers".
- Door Fallback Mode: Cards to be granted
access if the door controller module is unable
to communicate with the main panel. (Set this
to "10 Fallback Users").
Fall-Back Users (Can Enter During Comms Failure)
Configuration ÖSystem ÖAccess ÖSpecial