User`s guide

152 VEREX Director V4.73 User's Guide 21-0381E v4.7.3
screen in blue). Related Topics: Under "Account-
Wide Panel Settings", look for "Setup", then
"Escort-Required Mode".
Turnstile set for Antipassback
: To allow the escort to
badge again to gain entry, the reader must be set for
'turnstile' operation. Related Setting: Under "Reader
1 & 2 Settings for a Door", look for Special , then
Turnstile.
Escort/Dual-Custody for Readers
: Escort mode is
also supported for all cards at specific readers.
"Visitor" cards are denied access at readers set for
"Dual Custody". Related Topics
: Look for "Reader
Mode" in the reader configuration section for doors
and/or elevators (lifts).
Misc
: The 'visitor' setting is not available for escorts
(and vice-versa). As well, do not select "Master
Override" (previous/above)--as this will override the
visitor/escort feature.
- Wandering Patient: Sets associated users to
be tracked as they approach exterior doors, or
other areas of concern.
With this type of 'user', the 'access token' will typically
be a wireless wristband (with appropriate detection in
door frames).
When the patient approaches, an alarm can be
triggered, and the door can optionally lock as they
approach. Related Topic: Under "Doors, Readers,
and Related Settings", look for Special , then
Detect Wandering Patient.
- Reset Door Alarm: Provides associated staff
members with the authority to cancel a
'Wandering Patient' alarm by presenting their
(applicable/compatible) token at the specific
door.
- Panic Token: This designates associated user
'access tokens' as being a panic / duress
indication (instead of an access request).
In this case, the applicable 'access tokens' will
typically be separate wireless (RF) pushbuttons (with
appropriate detectors in the required areas). This is
typically used for areas such as parking garages.
- Group Number and Group Mode: Similar to
'Door Class'. Users can enter only at readers for
which their group number assigned here
supports the one set in each reader's
configuration.
Equality: Associated users will be able to enter at
readers set to the same group number as assigned
here.
Greater than or equal to
: Users will be able to enter
if their group number assigned here is greater than
or equal to that as set at each specific reader.
--------------------------------------------------------
Access Schedule
Note: Any three defined schedules can be assigned
throughout each authority (plus "Always" or "Never").
Per a Schedule
or 'Always': The area's schedule must
also be in effect unless either "Emergency Off" authority
is also provided (previous), or the area is set to "Allow
Out of Schedule Opens". Never
: Blocks the applicable
ability.
Tip: In the selections, "In Schedule" means during the
selected schedule, and "Out of Schedule" means after-
hours (i.e., outside of the selected schedule).
To define a schedule, refer to "Schedules for User
Access and Area Automation".
- Token Disarm - Level: Sets the arming-level
(Off or Stay) for an 'Auto-Disarm' when a user
associated with this authority gains entry to this
area. Choices also allow having this depend on
whether the event occurs during vs. outside of a
chosen schedule.
- Token Disarm - Areas: Pertaining to an 'Auto-
Disarm' (when a user associated with this
authority gains entry to this area), this sets
whether all areas in the authority will be
disarmed, or only the one being entered.
Choices also allow having this depend on
whether the event occurs during vs. outside of a
chosen schedule.
The auto-disarm feature will occur only for areas set to
"Auto Disarm On Valid Token" during certain times.
Details
: Configuration, ÖAreas, ÖScheduling.
Areas and Related Settings
- Door Commands: Determines if and when
associated users will be able to command doors
in applicable areas through LCD-keypads or this
software.
Elevators/Lifts and Floors: This selection applies to
elevator (lift) and floor control as well (if applicable).
- Door Class A/B/C Schedule: Determines if
and when applicable users will be able to enter
at readers set to allow access for any of these
door classes during certain times.
Door class restrictions can also be customized for
individual readers. Related Topics
: "Enable Class
Checking", and "[Class Map]" in the reader
configuration section for doors and/or elevators (lifts).
Master Override
: With 'Master Override' authority
(previous), these scheduled door class settings are
ignored (same as A/B/C – 'Always').
Arm/Disarm Authorities
: Inability to disarm also blocks
the ability to enter an armed area. (See " Arming
", previous.)