User`s guide

284 Guardall Director V4.74 User's Guide 21-0381E v4.7.4
5 P0 / P1fe 32 100 2048 1000 Yes 3d ID + Pin 60 / 100 /
250
Enterprise
6 P0 / P1fe 32 100 2048 2000 Yes 4d ID + Pin 60 / 100 /
250
Enterprise
7 P0 / P1fe 32 100 1024 4000 No 4d ID + Pin 60 / 100 /
250
Enterprise
8 P0 / P1fe, +½ 32 500 8192 10000 Yes 4d ID + Pin 60 / 100 /
250
Enterprise
9 P0 / P1fe, +½ 32 500 8192 10000 No 4d ID + Pin 60 / 100 /
250
Enterprise
10 P0 / P1fe, +1 32 500 8192 20000 Yes 5d ID + Pin 60 / 100 /
250
Ent. Elite
11 P0 / P1fe, +1 32 1000 16384 20000 No 5d ID + Pin 60 / 100 /
250
Ent. Elite
12 P0 / P1fe, +1 32 1000 16384 20000 Yes 5d ID + Pin 60 / 100 /
250
Ent. Elite
13 P0 / P1fe, +2 32 1000 65536 64000 No 5d ID + Pin 60 / 100 /
250
Ent. Elite
14 P0 / P1fe, +2 32 1000 32768 64000 Yes 5d ID + Pin 60 / 100 /
250
Ent. Elite
Supported 'feature-set' depends on your software
licensing (as managed through the license-manager
software). Feature-sets higher than 4 are supported
only with the "Enterprise" version of Guardall Director.
* Local user admin. (via keypad) is supported in all
systems, while local system configuration is supported
only in single panel systems set to "Feature Set" 1, 2,
3, or 4. Exception: Keypad programming is
supported in all systems for any 'application' modules
that require this due to custom settings stored only at
the module itself (HSC/printer module, RF/wireless
module, and Smart PODs).
For details on setting the 'memory model', refer to
"Account-Wide Panel Settings...".
Common Per-Panel Capacities
(not based on 'Feature-Set')
Expansion / Application Modules: 24
system LCD keypads and/or other modules, or
60 suite-security keypads (see exceptions).
Exceptions: Suite-security keypads can be mixed with
other modules if desired (the capacity for suite-security
keypads is reduced by 5
for each system LCD keypad,
and each other expansion / application module added.
(For example, with 2 system keypads, 3 door
controllers, and one point expansion module, a full-
capacity "Enterprise" system could still support 30 suite-
security keypads).
Converted TDC/PDC Door Controllers
: Up to 10 per
panel (combined total).
Areas: 16 monitored 'areas' per panel;
Doors:
The "Enterprise" version of the
software supports up to 32 doors per panel.
The "Prime" version supports a single panel
with 16 doors.
Note: To support doors/access-control, xL panels
(narrow mainboard), require a 'Feature Expansion
Board'.
Elevators: The "Enterprise" version of the
software supports up to 32 elevator (lift) cabs.
Exception
: This is shared with the door capacity (max.
32 combined total).
Floors:
The "Enterprise" version of the
software supports 124 unique access-
controlled floors.
(These can be in a single building,
or the combined total across multiple buildings.)
Monitored Sensors (Input Points):
(Depends on panel type, and number of point
expander modules.)
Up to 128: ISM panels (square mainboard).
Up to 256 (V4.4): xL panels (narrow rectangular
mainboard).
Input Capacity Detail:
ISM (square mainboard): 128 (120 external to the
main panel). All of these can be wireless if keypads
are set to zero each.
xL (narrow mainboard)
: 256 (all can be external /
wireless if the main panel and keypads are set to 0
each).
Also See:
- Expansion Modules (I/O tab, then "Inputs:")
- System Settings for each Panel (I/O Mapping tab)
Programmable Outputs: 128 per panel.