282 Guardall Director V4.74 User's Guide 21-0381E v4.7.4
(Any three-letter acronyms typically pertain to different
types of door-controller modules, and other
peripherals.)
To make use of your available capacities, the
panel "Feature Set" needs to be set
appropriately.
For details, refer to "Account-Wide Panel Settings".
Note: Some of the capacities that follow also require
additional panel memory to be installed (see the next
table). System upgrades may involve a combination of
upgrading software, hardware, and/or licensing (refer to
the instructions provide with the upgrade kit).
Software Versions and Basic Capacities
License => PRIME Enterprise Enterprise Elite
Users 1,000 10,000 64000
Doors *
(+ Elevators/Lifts)
16 * 1920 *
/ 3200 / 8000
1920 *
/ 3200 / 8000
Graphical User Interface
(floating licenses)
2 (V4.73) §
10 +1/+5 50 10 +1/+5 50
Communication Clients 1
3 / 10 / 25 3 / 10 / 25
Panels 1
60 / 100 250 60 / 100 250
Accounts 1
10 / 3000 †† 100 / 3000 ††
Visual Director (and
unlimited NetVision DVRs)
(V4.73)
Photo-badging
(V4.73)
Client/Server
Deployment
(V4.73) §
Database Views and
SQL Server Support
ERM Capability
"Adv. Features"
Remote Software
Download (V4.7)
(V4.73) §
VeDVR / NVe DVRs
-- +1 / +5 DVRs
1 only (V4.73) §
(V4.71)
1 - 1023
(V4.71)
1 - 1023
March Networks DVRs
-- +1 / +5 R5 DVRs
-- R4 DVRs (unlimited)
(V4.7)
1 - 1023
(V4.7)
1 - 1023
Notes and Exceptions
: Optional via licensing; § For new systems / updated hasp key only;
* To support doors/access-control and/or 'memory model' 4, xL panels (narrow mainboard) require a feature
expansion board; Client/Server operation also allows multi-server login; Adding panels allows for more areas,
sensors, doors, etc.; Elevator (lift) capacity is shared with the door capacity; Floor capacity is the same per panel
or account (124), and can be for one building, or shared across multiple buildings; Suite capacity is per panel, and
is reduced by 5 for each (other type of) hardware module present. †† Optional via HASP key. For a full SQL server
installation (not express) as set up and managed separately, and as selected during installation or through the DB
generator utility;
Note
: Playback for video events is NOT supported for March R4 DVRs.
Converted TDC/PDC Door Controllers
: Up to 10 per panel (combined total). The above lists show only the items that
are different between the two system versions. The sections that follow describe the overall maximum system
capacities. * Support for suite-security keypads requires a "Feature-Set" selection of 5 or higher. To set this value,
refer to "Account-Wide Panel Settings".