User`s guide

268 Guardall Director V4.74 User's Guide 21-0381E v4.7.4
(Although--with software and firmware
versions indicated above--a single HSC-IP
module can be used for both features at
the same time.
Networking Ports: The Director software
requires exclusive access to port 443, and
this port must NOT be blocked on the
network.
Set-up Overview:
Hardware: The IP module (and receiver)
must be set up--as applicable. Refer to
the documentation for the specific version
of IP module or receiver.
e.g., HSC-IP Module v4: 21-3691x
e.g., R1000 Receiver: 21-3690x
Certificate Files: Obtain through your
dealer.
Assign for the Director Server:
[Management], PC Access (+), Server Access.
Details
: Server Validation Certificates
Assign for each Communication Client:
[Management], PC Access (+), Client Access.
Details
: Client Access (Allowable Client List)
Assign for a Receiver (Monitoring via HSC-IP):
Refer to the programming guide for the receiver.
e.g., R1000 Receiver: 21-3690x
Director Software:
Client/Server via Secure IP: No set-up needed.
Exception
: If connecting out through a proxy-server,
some proxy information must be entered in the login
screen. Get an 'IT' person to help you with this.
PanelPC via Secure IP:
1) "Encrypted IP" must be selected for the
Communications Device, Communication Pool, and
Panel Group.
More
: Panel Connection Overview
2) Configuration, ->System, ->Communication.
All settings as usual, plus:
Interface IP Address: This is the IP Address or
name (FQDN) for the panel's IP interface--which
must also be as supported by the certificate.
Contact your IT rep. if you need assistance.
Interface IP Port: 443 (typical).
Monitoring via HSC-IP:
Configuration, ->System, ->Communication,
->SIP / HSC: SIP Mode: SIP over IP.
Note
: Firmware rev. levels, plus IP module set-up will
determine the use of HSC-IP protocol.
Basic IP Connections / Older
Firmware
Note: The Director software is backward-compatible
with existing IP connections. These are not
recommended for use on a public domain.
Beginning with version 3.30, the Guardall
Director software allows connecting to a panel
through an IP connection (LAN/WAN), and/or
reporting to a central monitoring facility through
an IP connection (SIP reporting).
The PC-to-panel connection via IP does not
require any specific revision of panel firmware.
The SIP reporting feature requires v3.30 panel
firmware or higher.
IP connections include an IP interface board
that must be properly set up for use with the
Guardall Director system.
All details on setting up an IP connection
are documented separately. For full
details, refer to the instruction manual
included with your IP interface board.
Tip: This may also be available on the Director
CD as a printable/viewable 'PDF' file.
Panel & Software Revisions: Guardall Director
software V3.2 and higher can connect with panels
V2.0 and higher.
Associated panels must be the same rev. level, and
the Director software must typically be upgraded to
the same level or higher.
Exception
: V3.3 panels OK with V3.20 software (if IP-
related features are not needed).
PC-to-Panel—Direct
Connection
Panel & Software Revisions: Guardall Director
software V3.2 and higher can connect with panels
V2.0 and higher.
Associated panels must be the same rev. level, and
the Director software must typically be upgraded to the