User`s guide
238 Guardall Director V4.74 User's Guide 21-0381E v4.7.4
System Version "E" Unconfirmed Alarm
System Version "E" Set/Unset
System Version "E" Freezer/Fire Fault
System Version "E" Bypass in Effect
System Version "E" Confirmed Alarm
Confirmed alarm – European Version (Active
when more than one detector is activated
during a single armed state).
System Version "E" Siren
System Version "E" Confirmed Alarm Strobe
System Cadence 0.5 Hz (1 sec on, 1 sec off)
System Cadence, 2 second on pulse on the minute
System Cadence, 10 second long pulse on the
minute
System - Cadence Selections
: These cannot be used
on their own (must be ANDed within an equation).
Version "E"
: Pertains to European monitoring
requirements.
Schedule (Pertaining to a specific schedule)
Schedule In Window (schedule active)
Schedule 15 Minutes Prior to "In Window"
(15 minutes before the schedule is active)
Schedule 15 Minutes Prior to "Out Window"
(15 minutes before the schedule ends)
Schedule Holiday in Effect (any type)
Schedule "No Access" Holiday in Effect
Holiday (if a specific Holiday is in effect)
Holiday Holiday in Effect
Area (if event occurs in a specific area):
Area Function key #0, #1, ...#9
(Pertains to keypad functions keys)
Area On
When the area is fully armed (ON).
Area Stay 2 (future use)
When the arming level is STAY 2 (future)
Area Stay 1
When the arming level is STAY.
Area Stay (1 or 2)
When armed to STAY. (Stay 2 = future)
Area Off
When the arming level is OFF
Area Not On
When the arming level is "Off" or "Stay".
Area Not Off
When the arming level is "Stay" or "ON".
Area Alarm
When area is in ALARM. Resets when
point(s) restore or follows siren timeout
(includes pseudos & tampers)
Area Was In Alarm
When area WAS IN ALARM. This is only for
input points in alarm e.g. NOT for system
trouble (clears when alarmed areas are
turned off then back on again)
Area Siren Fire (1 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 1 sec ON/OFF for
FIRE
Area Siren Fire (2 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 2 sec ON/OFF for
FIRE
Area Sonalert (E/E tones on Stay)
Follows sonalert, chime & provides Entry/Exit
tones when armed to STAY & ON
Area Sonalert (No E/E tones on Stay)
Follows sonalert, chime & does not provide
Entry/Exit tones when armed to STAY but
provides Entry/Exit tones in ON
Area Extended Delay Entry Tones
Follows Garage/extended delay Entry Tones
Area Bypasses
When any point in this area is BYPASSED
Area Fire
When any ‘FIRE’ type point in this area is in
alarm
Area Hold-Up
When any ‘HOLD UP’ type point in this area
is in alarm
Area Auxiliary Alert
When any ‘AUXILIARY ALERT’ type point in
this area is in alarm.
Area Vault
When any ‘VAULT / SAFE’ type point is in
alarm.
Area Burglary
When any ‘BURGLARY’ type point in this
area is in alarm.
Area Supervisory
When any ‘Supervisory' point is in alarm.