For Command Points: This selection does
not apply to command points (do not select
'Pre-Alarm Warning' for command points).
Transmit
- Off / Stay / On: The (applicable
area’s) arming levels for which an
alarm message will be transmitted to
the monitoring station whenever the
point is triggered;
For Command Points: Other than issuing
the specific action, command-points are
monitored only for 'Tamper' conditions.
Sonalert
- Off / Stay / On: The (applicable
area’s) arming levels for which keypad
sonalerts will be sounded for 1 second
when the point is triggered;
Siren
- Off / Stay / On: The (applicable area’s) arming
levels for which siren outputs will be sounded
when the point is triggered. (The “Siren Time” is
set through the System screen.)
For Command Points: Other than issuing the specific
action, command-points are monitored only for
'Tamper' conditions. So, the Transmit, Sonalert, and
Siren selections will take effect only for tamper
conditions.
Custom Circuit-Types for
Input Points
(V4.4)
Custom Circuit-Types
Newer styles of modules support custom
circuits for input points, while any older-style
modules will continue to support the standard
circuit-types.
Tip: Suitable default values are provided here for north
America, Europe, and UK-ACPO (per panel mode).
The defaults typically need to be changed here only for
sites that require custom/different values.
Note
: The specific circuit-type for each input point is
selected when setting up an input point (or suite-
security keypad).
How to Get Here
Multi-Account Systems: First select [Account Folders]
in the 'tree', and locate and double-click the desired
account.
MyTools Bar: Custom Circuit
In the Tree
: Configuration (+), Input Points,
Custom Circuit
(Under the specific panel group
and panel--if listed in the 'tree'.)
Related Topic: "Other Desktop Choices"
Tip: The Grid / Form toolbar-button allows selecting
your preferred view-mode (forms view is recommended
here).
Things You Can Do
View/Change a Custom Circuit Type:
1) Select the 'tab' for a desired circuit (1-4).
2) Select the desired circuit type near the top
of the screen.
3) Check the onscreen illustration to verify
your selection.
4) If needed, enter new resistor values, and
click [Calculate Thresholds].
For more information, refer to the item-
descriptions for this screen.
Circuit 1, 2, 3, or 4 )
- Circuit Type: This allows selecting from the
supported types of custom circuits;
Configuration, Input Points, Custom Circuit