User`s guide
21-0381E v4.7.4
Welcome Report Control Admin
Sys Config Tech-Ref
227
Input Points—Pre-Defined Sensor Types
Burglary Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx
Off
Tx
Stay
Tx
On
Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Entry Door Perimtr Door (area 1) Burg --
--
--
--
Entry Route 12hr E/E Route Burg
-- --
--
-- --
Perimeter Perimeter Immed Burg
--
--
--
Interior Motion 12hr Immed Burg
-- --
-- --
-- --
FAP - Motion 12hr FAP Burg
-- --
-- --
-- --
Day Warning 24hr Immed Burg
-- --
-- --
24hr Burglary 24hr Immed Burg
--
Life/Safety Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx Off Tx
Stay
Tx On Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Fire - A 24hr Immediate Fire-A
Fire 24hr 15s delay Fire
Fire 24hr Immediate Fire
Hold-up 24hr Immediate holdup
Aux Alert 24hr Immediate Emerg
Supervisory Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx Off Tx
Stay
Tx On Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Supervisory 24hr Immediate Spvsr
Local Points:
Type Arming Level Preprocess Class By-
pass
Chime Tx
Off
Tx
Stay
Tx
On
Sonlrt
Off
Sonlrt
Stay
Sonlrt
On
Siren
Off
Siren
Stay
Siren
On
Local - 24hr 24hr Immed Burg
Local-Stay&On Perimeter Immed Burg
Local-
Stay2 & ON
Perimeters Immed Burg
Local -
ON only
12 hr Immed Burg
Legend:
The 'Class' setting determines the type of
alarm message to be transmitted;
Bypass means whether or not the input point
will be bypassable;
Chime pertains to whether or not the
triggering of the input will cause audible
tones at keypads in the area (normally used
with Entry points/routes to let you know that
someone has entered);
Tx Off, Stay, and On pertain to the arming
levels for which activation of the input point
will cause an alarm to be transmitted to the
monitoring station;
Sonlrt Off, Stay, and On pertain to the
arming levels for which activation of the input
point will cause keypad 'sonalerts' in the
area to be sounded for one second.
Siren Off, Stay, and On pertain to the arming
levels for which activation of the input point
will cause siren outputs in the area to be
sounded.