User`s guide
21-0381E v4.7.4
Welcome Report Control Admin
Sys Config Tech-Ref
223
- Building Name: A suitable description
for the building or complex;
- Floor: The first column contains a
description for each floor. (Click within
the name field, and type a suitable
name);
To change the name for a floor, select the
present name, and enter the new name.
The top cell in this column does not pertain
to a floor.
Sort Order
: To maintain proper order
wherever floors are sorted by name, be
sure to select names accordingly (e.g., "15
Terrace", "14 Acme Offices", ..."01
Parking2").
- Floor Desecure Schedule: This
allows assigning individual schedules
to floors (for finer control than the next
field provides). (Select a schedule
here if desired and/or refer to the next field.)
Note: If more than one schedule is selected for a
floor, free access to the floor will be provided during all
times covered by any (one or more) of the schedules.
- Desecure Schedule 1/2/3: These columns
allow selecting up to three schedules during
which free access will be provided to any floors
selected. (Select a schedule at the top, and
then click each floor to be associated with that
schedule.)
Access to all floors from a specific elevator (lift) cab
can also be scheduled if desired. For details, refer to
"Elevators (Lifts) and Associated Readers".
Input Points—Monitored
Sensors
Input Points and Related Settings
Input points are the system’s way of monitoring
devices that detect smoke, motion,
door/window openings etc. in each area. The
Input Point screen allows fine-tuning basic
monitoring characteristics, identifying the area
the sensor is in, and whether or not it is on the
perimeter of that area.
Input Capacity Detail:
ISM (square mainboard): 128 (120 external to the
main panel). All of these can be wireless if keypads
are set to zero each.
xL (narrow mainboard)
: 256 (all can be external /
wireless if the main panel and keypads are set to 0
each).
Also See:
- Expansion Modules (I/O tab, then "Inputs:")
- System Settings for each Panel (I/O Mapping tab)
The point reset time is set globally for each account.
Related
: Account Information, Setup, "Point
Reset Time"
Account-Wide Panel Settings
Emergency Keys
: The first 3 inputs on system keypads
pertain to the built-in emergency keys rather than
external sensors.
Door Controllers and Suite-Security Keypads
: These
devices have built in dedicated inputs that are set up
directly under "Doors" or "Suite Security".
Many pre-defined input point types are
provided, in addition to custom input point
types for fine tuning the monitoring character-
istics to meet your specific requirements.
Custom point-types also allow setting up:
"Command Points"--allowing a button or sensor to
command a device (e.g., area, door) on any/all
panels;
Extended-delay sensors;
Vault/Safe input-points;
Guard-tour points (for guard-tour stations);
Area arm/disarm keyswitches, and;
Work-late buttons.
YourAccount Floors