User`s guide
21-0381E v4.7.4
Welcome Report Control Admin
Sys Config Tech-Ref
219
Pick-Lists (Bottom of the
Form)
-Panel Group & Panel references (optional):
This is where you select a specific panel-
group and panel in a multi-panel system
where the 'tree' is not
set to show items on
a panel-by-panel basis. For more
information on this feature, refer to "Other
Desktop Choices".
- Elevator: This is where you select an
elevator to view or edit. This area
shows a reference number assigned
by the system, and the name of the
elevator, once defined;
If the Name is Shown as "Door" (and the
form is blank): These screens are placeholders for
doors (click [Filter] on the toolbar to hide door
references).
"Offset" values for each panel determine whether
multi-panel sites will have consecutive versus
repeating elevator/door numbers. For details, refer to
the "Display Offsets" value under "System Panels and
Displayed Item-Numbers".
Top of the Form
- Name: A suitable name/location for the
elevator (lift) cab;
Standard
- Module: The number (from the MODULE
screen) for the elevator controller module
associated with the elevator cab.
- Port Number: Whether this is the 1
st
or 2
nd
elevator on the selected elevator-controller
module;
- Token Format: The card/token format
associated with this elevator (lift) cab. Up to
two card/token formats are supported for each
panel, as defined through the System Access
screen.
"Wiegand" pertains to cards/tokens for readers with
Wiegand data-format (Wiegand, Proximity, etc.).
Similarly, "Magstripe" pertains to cards for readers
with magnetic-stripe output (magstripe, bar-code, etc.).
For details on setting up the card/token format, refer to
"System Card-Access Settings".
- LCD Name: A shorter version of the name to be
displayed at LCD keypads. This is assigned
automatically, and can also be changed if
desired (max. 12 chars., plain text).
Extended
- Bi-Colour LED Mode: Select this if the reader
at this door has a single bi-colour LED (instead
of the two separate LEDs).
Note: Arming-stations are not supported in elevator
cabs.
- Insertion Type Reader: Ensures the access
card is not read more than once when
inserted and removed.
- Floor Button Monitor: Whether or not other
call buttons are to be disabled when a floor is
selected
(requires call-button-reporting wiring
between the elevator unit and our floor relay board)
.
- Floor Button Enabled Time: This is the
duration that the allowed floor call-buttons will
be available after a valid card is presented at the
reader in the elevator (lift) cab.
- Tamper Circuit: The type of circuit/wiring
associated with the reader tamper
input/sensor. ("Not Required" means this
connection is not being used/monitored.)
Reader
(Elevator (Lift) Reader Settings)
- In Area: This is the area associated with this
elevator cab.
Time and attendance reporting requires that all
readers used to exit from the "required attendance
zone" be set as "Outside".
This will typically pertain to the interior readers on the
perimeter of the facility, and may also include
additional readers (such as that allow entry to a
cafeteria or fitness room).
Configuration Elevators (1
st
tab shown)