User`s guide
216 Guardall Director V4.74 User's Guide 21-0381E v4.7.4
More Tabs
Request to Exit
Standard
- Request to Exit Required: Whether or not
the RTE (REX) button on the door-controller
module is being used.
- Log Request to Exit: Whether or not an
activity message is to be recorded each time
the RTE button is pressed.
- Request to Exit Circuit: This is the type of
circuit/wiring used with the RTE (REX) circuit for
this door.
Advanced
- Special Request to Exit Processing on
Panel: This puts the main panel in control of
the RTE processing (instead of the door
controller). This is for 'interlocked' doors
equipped with RTE buttons.
- Do not unlock on Request to Exit (bypass
door circuit only): This is for a monitored
door that does not have to be unlocked to exit
(avoids false "Forced Entry" alarms).
Tip: This can also be used with a motion sensor
instead of an RTE button.
Alarms
Door Held/Forced Setup
- Processing Required: Whether or not this
door is to be monitored for forced entry and/or
being held open too long.
- Door Held Open Time: This is the length of
time that the door can be held open (for a typical
entrant/user) before it considered to be an alarm
condition.
- Challenged/Extended Held Open Time: This
is the length of time that the door can be held
open before it considered to be an alarm
condition--after access was granted for a user
who is set for "Extended Delay/Challenged".
- Door Forced/Held Buzzer Time
(V4.4): Future
Use. This sets the buzzer duration for door held
open and forced entry alarms.
Held Open Alarm
- Transmit / Sonalert / Siren: The area arming
levels for which a 'Door Held Open' alarm will
be transmitted, and/or cause a local sonalert
or siren to be sounded.
Forced Open Alarm
- Transmit / Sonalert / Siren: The area arming
levels for which a 'Door Forced Open' alarm will
be transmitted, and/or cause a local sonalert or
siren to be sounded.
Aux In/Out
Auxiliary Input
- Mode: This specifies how the auxiliary input on
this door-controller module is to be used (none,
monitor mag. lock, or as an Exit/RTE (REX)
button used to trigger a door opener).
Process Panel as Input Point: Future Use. Allows the
auxiliary input for this door to be reserved (at the
module), defined, and configured as a regular system
input point.
Converted PDC door controllers do not support an
auxiliary input.
- Auxiliary Input Circuit: This is the type of
circuit/wiring used with the auxiliary input circuit
for this door.
MagLock Alarm
- Transmit / Sonalert / Siren: The area arming
levels for which a 'Mag Lock Bond Sense'
alarm will be transmitted, and/or cause a local
sonalert or siren to be sounded.
Auxiliary Output Relay
- Mode: Future Use. This specifies how the aux.
output relay on the door-controller module is to
be used (signal Door Held Open and Forced
Entries, or to trigger an automatic door opener).
Note: The "Door Opener" setting can alternatively be
used with 'Card Disable' applications (e.g., turnstile
card capture).
Locator (previous/above)
:
In Reader (or out reader),
[Card Action], (Card Action=Disable Cards;
Option=... : Auxiliary Output).
Panel Control
: Future Use. Allows the auxiliary
output relay for this door to be reserved (at the
module), defined, and configured as a regular system
output point.
- Time: This is length of time that the auxiliary
relay on the door-controller module will remain
energized each time it is triggered.