To have the door simply re-lock at the closing time, set
the "In Schedule" value as desired, and set the "Out of
Schedule" value to "Locked".
To have the door unlocking follow the area arming-
state only, set the schedule to "None", and "In
Schedule" to either "Area is Off", or "Area is
Stay/Off", as desired.
If you do not
want the door to unlock automatically
based on a schedule and/or the area arming-state, set
the "Schedule" to "None", and the 'In Schedule' value
to "Locked".
Circuit
With converted TDC/PDC door controllers, this setting
does not apply.
- Reader Tamper Circuit: This is the type of
circuit/wiring used with the reader tamper circuit
for this door.
Not Required: This disables the reader tamper input
(i.e., the tamper input will not be monitored).
Converted TDC/PDC Door Controllers
: These units
do not support dedicated/separate reader tamper
monitoring.
- Door Circuit: This is the type of circuit/wiring
used with the door contact for this door.
-------------------------
- Process Reader Tamper as Input Point:
Future use.
Other
- Door Arming Level: The area arming levels
for which the door is to be monitored.
Tip: You may wish to use "Stay and On" with doors
used to enter the facility, and "On Only" for all doors
within
the facility.
- Bi-Colour LED Mode: Select this if the reader
at this door has a single bi-colour LED (instead
of the two separate LEDs). This setting must
also be used if an 'arming station' is present.
Note: Arming-station wiring differs from other readers
(ensure the proper installation instructions have been
followed).
- Entry Detect: If selected (), persons will not
be considered "In" the new area if they are
granted entry, but do not open the door.
Tip: This affects the in/out status of applicable users,
and allows them to badge again to gain entry with
antipassback turned on (see "Detect Antipassback", to
follow / below).
Related
: Configuration Areas
Counting and Auto Arm.
Note: This does NOT affect 'Activity' detection
(Cfg.Areas Activity).
Reader 1 & 2 Settings for a Door
Defining a ‘Required Attendance’ Zone
For time and attendance reporting, a ‘required
attendance zone must be defined by setting
the "Area" as "Outside" for all readers used to
exit
from this zone.
See the "Area" description for more information.
Note: For proper time and attendance tracking, there
must be no other way to exit from the required-
attendance area (all exit doors must have a reader).
In Reader
(and 'Out Reader'--if applicable)
Note: "In Reader" pertains to the 1
st
(or only) reader for
this door. "Out Reader" pertains to the 2
nd
reader for
this door (if applicable).
The second reader, and In/Out processing is NOT
supported on the older (2-reader) version of the door
controller module.
- Access to Area: This is the area associated
with this reader (i.e., the area being entered
when using this reader).
Time and attendance reporting requires that all
readers used to exit from the "required attendance
zone" be set as "Outside".
This will typically pertain to the interior readers on the
perimeter of the facility, and may also include
additional readers (such as that allow entry to a
cafeteria or fitness room).
Card Mode
- Schedule, and In / Out of schedule: These
settings specify the basic method that
entrants will have to use to gain entry at this
door—i.e., via access token with or without
keying-in a PIN at the reader. If scheduled,
different entry requirements can be selected
for when the schedule is active versus outside
of the chosen schedule.
UID vs. Card Number: The system can be set to
require a full card number instead of the user-ID
number. (Wherever you see "UID", a card number
would have to be entered instead.)
Related Topic
: Account-Wide Panel Settings (look for
"Setup", and then "User Logon Mode").