User`s guide
21-0381E v4.7.4
Welcome Report Control Admin
Sys Config Tech-Ref
199
- Allow Out of Schedule Opens: Whether or not
users without
'Emergency Off' authority will be
able to gain entry and/or disarm this area
outside of its open/close schedule, and/or adjust
the area closing time (i.e., 'worklate') after their
schedule has expired. (For a non- scheduled
area, this concept does not apply, since only
'Disarm' authority would be required.)
Related Topic: "Authorities for Users/Entrants".
Auto Disarm on Valid Token Mode (V4.4)
- In Schedule: Sets whether or not auto-
disarming will occur for this area (see note)
while
the area schedule is active, and what
arming state will be applied (per user authorities,
or 'Off' or 'Stay' regardless of the user
authorities);
Note: This pertains to the area disarming
automatically when an authorized person is granted
entry.
Unscheduled Areas
: For an unscheduled area, the 'In
Schedule' selection will remain in effect 24/7 (same as
a schedule that's always active).
- Out of Schedule: Sets whether or not auto-
disarming will occur for this area (see note,
previous) after-hours
(i.e., outside of the
schedule), and what arming state will be applied
(per user authorities, or 'Off' or 'Stay' regardless
of the user authorities);
Tip: The 'auto-disarm' feature can be customized for
groups of users as per their assigned 'authority' profile.
Details
: YourAccount, Authorities, (Area
Attributes), Access Schedule
Authorities for Users/Entrants
Stay-Off-Stay Scheduling
- Schedule: A schedule to be associated with
automated stay/off/stay arming in this area (also
see next setting).
Tip: Pause the mouse cursor over a schedule in the
list to see the settings for that schedule.
- Auto Stay Mode: Specifies that the area will
automatically switch from 'Stay' to 'Off', and then
'Off' to 'Stay', in-sync with schedule chosen
above. This will not occur if the area is fully
armed (ON) at the applicable times.
+ None: Disables this feature (same as selecting
"None" for the schedule.
+ Non secure Disarm to Off: The area will disarm
(e.g., at the start of the day) if it is in 'stay' mode at
the specific time;
+ Secure Disarm to Off: For the area to be
disarmed (to off) at the scheduled time, the area
must be armed to 'Stay', and it must have been fully
armed once since the last cycle (ensures someone
was in the facility to arm the area at some time);
+ Disarm to Off Pending First Valid User: The area
will disarm to off if it is in 'stay' mode at the
scheduled time, but the change will not
occur until a
valid user is granted access into the area.
Counting ( V4.20)
These selections pertain to monitoring the number of
people (or vehicles, etc.) in an area at any one time (per
access-granted), and whether or not the area can be
armed with persons still listed as being in the area.
User Counter
- Maximum: (0 - 16383) The maximum number
of users/vehicles allowed in an area before its
status will be "full".
Tip: This can be used to trigger an output (e.g.,
"Parking Lot Full" sign).
Minimum: (0 - 15) The number of users that
can be present with the area still being
considered 'empty'';
Count Mode: The method for counting users in
the area.
Normal: Area entering = +1, area leaving = -1.
Special (APB-based)
: Area entering = +1, last known
area = -1.
(Exception: Same as 'Normal' for "Timed APB" once
the timer expires.)
Blind Count
: Counts each time a card/token is
accepted—even if you end up 'badging' more than
once.
Warning Level on Arm: Whether a person
trying to arm this area when it isn't listed as
"Empty" will only be warned, or whether arming
will be blocked altogether (manually vs. any
method);
User Counter Reset
These settings allow the user-count for a scheduled
area to be reset (to zero) automatically under certain
conditions.
Reset before 'in schedule': This resets the
area user-count automatically at a relative time
of day (a specified number of hours before the
beginning of the area's schedule);
Reset on Disarm to OFF: Whether or not the
area user-count will be reset automatically
whenever the area is disarmed to "Off";
Reset on arm to ON: Whether or not the area
user-count will be reset automatically whenever
the area is armed to "On".
Related: Configuration Doors Extended
"Entry Detect"; Configuration Output Points