User`s guide
21-0381E v4.7.4
Welcome Report Control Admin
Sys Config Tech-Ref
193
- Position: The position of the odd-parity
'checksum' (1-40);
- Start: The starting position of the data being
checked for odd-parity (1-40);
- Length: The number of digits being checked for
odd-parity (1-40).
Even Parity
These settings pertain to even-parity checking, which
helps to identify card 'misreads'.
- Position: The position of the even-parity
'checksum' (1-40);
- Start: The starting position of the data being
checked for even-parity (1-40);
- Length: The number of digits being checked for
even-parity (1-40).
Special (Miscellaneous Items)
- Door Fallback Mode: Cards to be granted
access if the door controller module is unable
to communicate with the main panel
database:
:
None: No cards/tokens accepted;
Valid Token Format: All readable
cards/tokens accepted;
Valid Site Code: All cards/tokens with the
correct site code will be granted access;
10 Fall-back Users: Only the users who are
assigned as 'FallBack Users'. For details,
refer to "Fall-Back Users...".
- Unlock All Doors On Fire Alarm: If selected,
all doors in all areas associated with this
panel will automatically unlock when a fire
alarm is detected by this panel.
- AutoUpdate Card Version: For fixed-ID
cards with a version number, this sets how re-
issued cards are to be handled.
= Grant access to a card with higher version
number, and update the version number for the
specific user automatically;
= Only cards that match the version number for
each user will be granted access (must update
manually when a card is re-issued).
To set the initial/actual version number for specific
card(s), refer to the section on "Users".
For additional related settings, refer to "Card Version"
(previous). Panel Version
: This feature requires V3.2
panel firmware.
Equipment Settings (Pseudo
/ Internal Inputs)
Equipment Settings for a Panel
The Equipment screen includes monitoring /
signalling settings pertaining to various events
associated with a specific panel (and/or
expansion modules). These can also be
thought of as 'pseudo' or 'internal' input points.
How to Get Here
Multi-Account Systems: First select [Account Folders]
in the 'tree', and locate and double-click the desired
account.
MyTools Bar: System Equipment
In the Tree
: Configuration (click the "+"),
System, Equipment
(Under the specific panel
group and panel--if listed in the 'tree'.)
Related Topic: "Other Desktop Choices"
Tip: The Grid / Form toolbar-button allows selecting
your preferred view-mode.
Things You Can Do
View/Change an Equipment Selection
(Monitored Condition ): Select one from
the pop-up list at the bottom of the form.
Tip: You can also use the 'browse' buttons to quickly
scan through the defined items.
Blocking an Item from being monitored
by the system: Select the specific item,
and then set its 'preprocess' to 'disabled'.
Grid View: Scan the list as desired. Tip: You can
resize or maximize the window as desired, or use the
bottom scroll-bar to view additional columns.
For a list of the specific events, refer to the Equipment
screen in the Guardall Director software.