groups of areas will be supported through
LCD keypads associated with this panel.
Group or Area: This will prompt LCD keypad users to
select an area group, or an individual area.
Remote Area or Group
(V4.5): Allows
simultaneously arming or disarming like-named groups
of areas across multiple panels from a single keypad
for users with applicable authority.
Related: Configuration, Areas, Area Group
Area Groups and Multi-Panel Arm/Disarm
- Prompt for Entry Delay on LCD Keypad:
Whether or not the user will be asked if they
want the optional entry delay each time any area
is set to STAY. (An entry delay provides time
for an authorized entrant to disarm the area.)
- Ring Back Required on Arming: Whether or
not the monitoring station will cause a keypad
tone and short siren squawk to confirm each
time an area is armed--as required for UL-listed
systems.
ACPO
Note: This tab appears only for panels set for UK
(ACPO) operating mode. For a new system, this is set
through a small wizard screen when the account is
created.
- Confirm alarm timeout: This is the allowed
duration/time during which an alarm can be
confirmed;
- Confirmed reset service: Whether or not a
confirmed alarm can be reset locally using the
service PIN;
- Confirmed reset master: Whether or not a
user with master authority can reset a confirmed
alarm locally;
- Confirmed reset managed: Whether or not
any valid user can reset a confirmed by entering
a PIN obtained by calling the central monitoring
facility/station;
- Confirmed reset remote: Whether or not
confirmed alarms can be reset remotely through
a software utility running at the central
monitoring facility/station;
- Unconfirmed Reset Mode: Future use.
Monitoring, Numeric Paging, &
Remote Mgt. Settings
The System Communication screen
This screen provides access to monitoring,
numeric paging, and communications settings
for a specific panel.
Tip: Beginning with Guardall Director V4.0, you can use
Wizards to set up a new system, and initiate
communications with panels. (Look in the T
ools
menu).
How to Get Here
Multi-Account Systems: First select [Account Folders]
in the 'tree', and locate and double-click the desired
account.
MyTools Bar: System Communication
In the Tree
: Configuration (click the "+"),
System, Communication
(Under the specific
panel group and panel--if listed in the 'tree'.)
Related
Topic: "Other Desktop Choices"
Tip: The Grid / Form toolbar-button allows selecting
your preferred view-mode (forms view is recommended
here).
Things You Can Do
View or change settings as desired for the
specific panel (see the selection-descriptions).
Setting a Panel to Automatically Dial-In
and Transmit Messages to Guardall
Director
Panels with their own dedicated external
modem (or IP interface--if V3.3 Director) can
be set to automatically dial-in and transmit
messages to the Guardall Director system.
(In other configurations, the messages are transmitted
when a connection is made with the specific
panel/account—either manually by an operator, or
through a scheduled/repeating communications session
that was set up previously.)
First, check that the "Panel Groups" for each
applicable panel contain no other panels (one
panel per 'Panel Group').