User`s guide
172 Guardall Director V4.74 User's Guide 21-0381E v4.7.4
- Arm/Disarm and Tones
(V4.4): Sets
whether or not disarming will be supported
through keypads and the general operation of
the keypad sonalert/buzzer.
Related: “Keypad Tone Reference”.
Card Action
- Ignore Pending Enrolment: This sets card-
enrolment readers to work on expired/disabled
cards whether set for "pending enrolment" or
not. If not selected, card-enrolment readers will
affect only cards set as "pending enrolment".
Application Tip: Cards can be set as 'Pending
Enrolment' manually (e.g., when first issued), or when
accepted at a reader set to do this. 'Expired' cards
also includes cards that had been previously enabled
for a set period of time by a reader set to do this.
Related Settings
:
Users, Validation, Pending Enrolment.
See: Users (Entrants/Panel Users).
Configuration, Doors, In Reader (or out...),
[Card Action].
See
: Reader 1 & 2 Settings for a Door.
Bad Card/PIN ( V4.20)
These selections pertain to how the system will respond
to repetitive invalid cards and/or invalid PINs at a reader
or LCD keypad (i.e., an unauthorized person trying to
gain entry).
Related
: Control & Status Panel Control & Status
System [Clear User Lockout]
Invalid User Detection
- Maximum Bad PINs: The number of invalid
PINs that can be entered before that person will
be locked out.
- System Lockout Duration: The duration that
all users will be locked out in response to
repetitive invalid access attempts from multiple
users. This pertains to 'global lockouts'.
- Maximum Lockouts Before Global Lockout:
The number of individual users that can be
locked out for an account before triggering a
'Global Lockout' condition. This: Will generate
a local alarm message; Can be transmitted to a
monitoring facility (setting to follow); Can be set
to block access to all users on an area by area
basis.
Related: Configuration Areas Access "Bad
Card Action"
Tip
: A global lockout can be removed through:
Control & Status;
Visual Director, and/or: A 'Command Point' custom
input.
- User Lockout Duration: The duration that
users will be locked out in response to repetitive
invalid access attempts.
Tip: Long duration and/or permanent 'lockouts' can be
removed through: Control & Status; Visual Director;
A 'Command Point' custom input.
- Invalid Card Detection: Allows turning invalid
card detection on or off, and setting the type of
invalid cards to be counted.
Invalid Cards: Cards denied access due to:
Not in database; Wrong site number;
Wrong version number;
High Risk
: Cards denied access due to: Card
expired; Schedule expired; Interlock violation;
Reader locked out; Wrong area.
- Maximum Invalid Cards: The number of times
an invalid card can be presented before that
card will be locked out (for the 'User Lockout
Duration');
- Transmit Global Lockout Alarm: For a
centrally-monitored facility, this determines if
'global lockouts' are to be transmitted to the
monitoring station.
Site Address and Mailing
Address
- Name: The name/description for the
site/account (as set through the "Standard" tab).
- Address: The address/location of the
site/account.
- [Copy Site Address to Mailing Address]: This
sets the "Mailing Address" to match the present
"Site Address".
Contact
- Phone: The voice/contact phone number for the
person who looks after the system.
- Contact: The on-site contact person for the
site/account.
- Comments: Additional information pertaining to
this site / account (optional).
Service PIN
This pertains to the service user/login (000) with access
to all features including configuration menus, service