Cells Per Unit 6
Voltage Per Unit 12
Capacity 40Ah @ 20hr-rate to 1.75V per cell @25
(77 )
Weight Approx. 12.73 kg (28.06 lbs)
Maximum Discharge Current 400A(5sec)
Internal Resistance Approx. 10 m
Operating Temperature Range
Nominal Operating Temperature Range 25
3 (77 5 )
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25
(77 )
Recommended Maximum Charging 12 A
Current Limit
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25
(77 )
Self Discharge CSB Batteries can be stored for more than 6 months at
25
(77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
L terminal:B2 or Recessed type to accept M6 bolt
Container Material ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
~40 ( 5 ~104 )
Storage: -15
~40 ( 5 ~104 )
Constant Power Discharge Characteristics
Unit:W
(25
,77
)
Constant Current Discharge Characteristics
Unit:A
(25
,77
)
EVX 12400
12V 40Ah
Specification
Powered by
EVX 12400 is designed specially for electric vehicles,
such as electric golf cart, electric wheelchair, mower,
dust collector...etc. It has high cycling life, high
efficiency and long service life.
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
38.1 22.9 16.8 13.4 9.75 7.76 6.42 4.31 3.59 2.17
1.67V
37.0 22.3 16.3 13.0 9.47 7.52 6.24 4.18 3.49 2.12
1.70V
35.8 21.7 15.8 12.7 9.17 7.33 6.07 4.05 3.40 2.05
1.75V
34.8 21.0 15.3 12.3 8.88 7.09 5.91 3.94 3.30 2.00
1.80V
33.7 20.3 14.8 11.9 8.58 6.89 5.70 3.82 3.17 1.94
1.85V
32.6 19.5 14.4 11.4 8.29 6.63 5.48 3.68 3.09 1.89
F.V/Time 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR
1.60V
457 275 201 162 117 93.0 76.8 49.9 41.1 22.3
1.67V
444 268 196 157 113 90.1 74.6 48.4 40.0 21.6
1.70V
430 260 189 152 110 87.6 72.3 46.9 38.8 20.9
1.75V
417 252 184 147 107 84.5 69.9 45.5 37.6 20.3
1.80V
404 243 178 143 103 81.5 67.4 44.0 36.4 19.6
1.85V
391 235 173 138 99.5 78.9 64.9 42.6 35.2 19.0
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H) Container height (h) Length (L)
170±2 (6.69±0.08) 168.5±2 (6.63±0.08) 197±2 (7.76±0.08) 165±2 (6.5±0.08)
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified
RA1403
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
Drawing of recessed terminal