Instruction manual

www.cs-instruments.com
5
Multifunktion
Anwendungstechnische Merkmale
der Verbrauchszähler VA 420:
Description Order no.
DS 500 - intelligent chart recorder in basic version (4 sensor inputs) 0500 5000
Option 4 additional sensor inputs for DS 500 Z500 5001
Option 8 additional sensor inputs for DS 500 Z500 5002
Option Integrated webserver Z500.5003
Option "consumption report" statistics, daily/weekly/monthly report Z500.5004
Option "quick measurement with 10 msec sampling rate” for analogue sensors
Z500.5005
Option version for panel mounting Z500.5006
Option power supply 24VDC (instead of 100...240 VAC) Z500.5007
CS Soft Basic for DS 500 - data evaluation in graphic and table form, 0554.7040
reading out of the measured data of one DS 500 via USB or Ethernet
CS Soft Network - Database Client/Server Solution (up to 5 DS 500) - 0554.7041
database (MySQL) to Server - data evaluation via Client-Software
CS Soft Network - Database Client/Server Solution (up to 10 DS 500) - 0554.7042
database (MySQL) to Server - data evaluation via Client-Software
CS Soft Network - Database Client/Server Solution (up to 20 DS 500) - 0554.7043
database (MySQL) to Server - data evaluation via Client-Software
CS Soft Network - Database Client/Server Solution (> 20 DS 500) - 0554.7044
database (MySQL) to Server - data evaluation via Client-Software
Input signals
Current signal (0...20mA/4...20mA)
internal or external power supply
Measuring range 0…20 mA
Resolution 0.0001 mA
Accuracy ± 0.003 mA ± 0.05 %
Input resistance 50
Voltage signal (0...1 V)
Measuring range 0…1 V
Resolution 0.05 mV
Accuracy ± 0.2 mV ± 0.05 %
Input resistance 100 k
Voltage signal (0...10 V / 30 V)
Measuring range 0…10 V
Resolution 0.5 mV
Accuracy ± 2 mV ± 0.05 %
Input resistance 1 M
RTD Pt 100
Measuring range -200…850° C
Resolution 0.1° C
Accuracy ± 0.2°C (-100...400°C)
± 0.3°C (further range)
RTD Pt 1000
Measuring range -200…850° C
Resolution 0.1° C
Accuracy ± 0.2° (-100...400°C)
Pulse
Measuring range min pulse length 100 μs
frequency 0...1 kHz
max. 30 VDC
Technical data DS 500
Dimensions of housing 280 x 170 x 90 mm, IP 65
Connections 18 x PG 12 for sensors and supply, alarm relays
1 x RJ 45 Ethernet connection
Version panel mounting Cutout panel 250 x 156 mm
Weight 7.3 kg
Material Die cast metal, front screen polyester
Sensor inputs 4/8/12 sensor inputs for analogue and digital sensors
freely allocatable. See options
Digital CS sensors for dew point and consumption with SDI
interface FA/VA 400 Series,
Digital third-party sensors RS 485 / Modbus RTU, other
Bus systems realizable on request
Analogue CS sensors for pressure, temperature, clamp-on
ammeters preconfigured
Analogue third-party sensors 0/4 ..20 mA, 0..1/10/30V, pulse,
Pt 100 / Pt 1000, KTY
Power supply for 24 VDC, max. 130 mA per sensor, integrated mains unit
sensors max. 24 VDC, 25 W
in case of version 8/12 sensor inputs 2 integrated mains units
each max.24 VDC, 25 Watt
Interfaces USB stick, USB cable, Ethernet / RS 485 Modbus RTU / TCP,
SDI other bus systems on request, WEB server optionally
Outputs 4 relays (changeover contact 230 VAC, 6 A), alarm management,
relays freely programmable, collective alarm
Analogue output, pulse in case of sensors with own
signal output looped, like e. g. VA/FA Series
Memory card Memory size 2 GB SD memory card standard,
optionally up to 4 GB
Power supply 100...240 VAC / 50-60 Hz, special version 24 VDC
Colour screen 7" touch panel TFT transmissive, graphics, curves, statistics
Accuracy see sensor specifications
Operating temperature 0...50°C
Storage temperature -20...70°C
Optionally Web server
Optionally Quick measurement with 10 ms sampling rate for analogue sensors,
Max/Min indication per second
Optionally Option "consumption report” statistics,
daily/weekly/monthly report