Instruction manual

36
www.cs-instruments.com
Flow station DS 300
with consumption counter
Consumption
DS 300 displays the actual value (m
3
/h,
m
3
/min) and the total consumption.
A 4...20 mA output for m
3
/h and a pulse
output for m
3
are available for routing to a
superior building management system
(PLC)
Special features
Usable from 1/2” to 12” (DN 300)
All-in-one solution, small
installation expenditure
2 displays, actual flow and total
consumption
Easy installation and removal of the
sensor under pressure
Highest accuracy due to 5 point
precision calibration
Output 4 to 20 mA for m
3
h,
pulse output for m
3
Easy handling:
– Inner diameter freely adjustable
in DS 300
– 2 alarm values freely adjustable
– Optical display in case of alarm
– Consumption counter resettable
Dew point sensor connectable
Flow measuring ranges VA 400 for compressed air (ISO 1217: 1000 mbar, 20°C)
The large measuring range of the
consumption sensors enable the
recordings of high consumptions
(e. g. on weekdays) and the determination
of leakages of a few litres/min
(e. g. weekends).
Flow station DS 300 with
consumption counter
consisting of:
Multifunction measuring
instrument DS 300
Consumption probe VA 400
Available with and without
measuring section
Installation even under pressure via
customary 1/2” ball valve
Inner diameter of pipe VA 400 Standard VA 400 Max. VA 400 HighSpeed
(92.7 m/s) (185.0 m/s) (224.0 m/s)
Inch mm Meas. ranges Meas. ranges Meas. ranges
from ... to from ... to from ... to
1/2” 16.1 DN 15 2.5...760 l/min 3.5...1516 l/min 6.0...1836 l/min
3/4” 21.7 DN 20 0.3...89 m
3
/h 0.4...178 m
3
/h 0.7...215 m
3
/h
1” 27.3 DN 25 0.5...148 m
3
/h 0.6...295 m
3
/h 1.1...357 m
3
/h
1 1/4” 36.0 DN 32 0.9...280 m
3
/h 1.2...531 m
3
/h 2.5...644 m
3
/h
1 1/2” 41.8 DN 40 1.2...365 m
3
/h 1.5...728 m
3
/h 3.0...882 m
3
/h
2” 53.1 DN 50 2...600 m
3
/h 2.5...1198 m
3
/h 4.6...1450 m
3
/h
2 1/2” 71.1 DN 65 3.5...1096 m
3
/h 5...2187 m
3
/h 7...2648 m
3
/h
3” 84.9 DN 80 5...1570 m
3
/h 7...3133 m
3
/h 12...3794 m
3
/h
4” 110.0 DN 100 9...2645 m
3
/h 12...5279 m
3
/h 16...6391 m
3
/h
5” 133.7 DN 125 13...3912 m
3
/h 18...7808 m
3
/h 24...9453 m
3
/h
6” 159.3 DN 150 18...5560 m
3
/h 25...11097 m
3
/h 43...13436 m
3
/h
8” 200.0 DN 200 26...8786 m
3
/h 33...17533 m
3
/h 50...21230 m
3
/h
10” 250.0 DN 250 40...13744 m
3
/h 52...27429 m
3
/h 80...33211 m
3
/h
12” 300.0 DN 300 60...19815 m
3
/h 80...39544 m
3
/h 100...47881 m
3
/h
engraved
depth scale
safety ring
mounting depth
= x + y
d
A
= outer diameter
x =
y
x
d
A
d
A
2