The measuring instrument DS 300 mobile
enables the analysis of compressed air
stations. Up to 4 clamp-on ammeters
measure the current consumption of every
single compressor. Optionally also
4 pressure sensors, temperatrure sensors or
any other analogue sensors can be
connected.
In addition, the DS 300 mobile measures
the discharged compressed air in m³/h, m³
and the dew point temperature in °Ctd at
the same time.
The integrated data logger stores up to
1 million measured values.
The CS analysis software enables the
graphical and statistical evaluation of the
stored data at the PC.
From the stored current values it is
possible to calculate the costs in € for
the energy consumption (kWh) as well
as the load and idle times of every single
compressor including switch-on/switch-off
cycles.
The costs per m³ and the total costs per
year in € are calculated from the actually
consumed quantity of compressed air.
A special leakage calculation determines
the cost share of the leakages in
comparison to the total costs in €.
For documentation of the measured
values the user gets a DIN A 4 graphics
printout for each compressor in a day view
and in a week view at the touch of a
button.
The additional printout with the statistical
values contains all necessary data for a
complete analysis of the compressor stations
(see page 32).
Complex Excel® calculations and the issuing
of reports are no longer necessary. Each ser-
vice company can issue a report for the end
customer with their own logo and additional
information.
Compressed air analyzer DS 300 mobile
Energy analysis – consumption measurement – leakage calculations at