Instruction manual

28
www.cs-instruments.com
Easy and affordable installation
Units freely selectable via keypad m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm
Compressed air counter up to 1,999,999,999 m³. Resettable to "zero" via keypad
Analogue output 4...20 mA, pulse output (galvanically separated)
High measuring accuracy also in the lower measuring range
(ideal for leakage measurement)
Negligibly small loss of pressure
Calorimetric measuring principle, no additional pressure and temperature
measurement necessary, no mechanically moved parts
Gas types adjustable via software (nitrogen, oxygen, CO
2
, nitrous oxide, argon)
Compressed air balancing, com-
pressed air consumption measurement
Leakage air / leak rate determination
Flow measurement of process
gases like e. g. nitrogen, CO
2
,
oxygen, argon, nitrous oxide
Flow measurement at nitrogen
generators
Easy installation into the existing pipeline
due to integrated measuring section
and weld neck ange
(according to EN 1092-1 PN 40)
High measuring accuracy due
to defined measuring section
(inlet and outlet section).
At the touch of a button:
– reset of counter reading
– selection of units
Application-technological features of the
consumption counters VA 420:
Application range of
VA 420:
Consumption
VA 420 The advantages at a glance
4…20 mA output for actual consumption
Pulse output for total consumption (counter reading)
Measuring device removable:
Dismounting of the whole measuring section
is not necessary, no bypass required.
Display twistable by 180°
Display shows 2 values:
Actual consumption in m³/h, l/min,…
Total consumption (counter reading)
in m³, l
Values indicated in the display turnable
by 180°, e. g. in case of overhead
installation