User manual
Page 26 U S E R M A N U A L AUTOSAT 2 CONTROL
9 Specification
Power supply:
Supply voltage (max. ratings) 10...15V DC
Voltage on control line D+ 10...30V DC
Current / Power input
Search mode typ. 3 A / 36 W
Reception mode typ. 0,01 A / 0,03 W
GPS (optional) 0.25 A / 3 W
Current limit, motors approx. 8 A
LNB:
LOF 9.75 / 10.6 MHz
Noise level low / high band single LNB 0.3 dB
twin LNB 0.4 dB
LNB-control 14/18 V, max. 400 mA
Measurements:
Control unit: 200 x 150 x 70 mm (W x H x D)
Approval by the German Federal Motor Transport
Authority (KBA) of the EEC type label (e1) according to
the EMC Directive 2005/83/EG for installation and
operation in motor vehicles.