Specifications

Technology Upgrade Security Cameras-Axis 28 3700-5
1224_01
B. Exterior cameras shall be mounted securely to the structure and shall be sealed to prevent
water or any other environmental condition to enter the camera.
1. Provide the correct mount for the location of each exterior camera.
2. Where the mount is to the outside of a building then the contractor shall install a
conduit from the exterior camera to the inside of the building for the camera cable(s).
3. Review mounting location to determine optimum height of camera to cover all areas
and provide the clearest pictures. Mount at appropriate height.
4. Work with the Owner to focus and align all cameras for maximum coverage.
5. Contractor shall change lenses for different focal lengths based on the actual
installation location of the cameras and the requirements of the Owner.
6. Seal around all conduit openings and the camera mount to seal from water and air
infiltration.
7. Install patch cable through the conduit and connect to the CAT-6 cable on the interior
of the building.
C. Interior cameras shall be mounted in the lay-in ceiling, supported from the open ceiling or to
the wall with a structural mount.
1. The Contractor shall work with the Owner to determine the location of all the
cameras.
2. Work with the Owner to determine the direction of the lens and its focal length.
3. Ensure that the camera is mounted securely to the drop ceiling and is supported from
the T-bar.
4. Contractor shall change lenses for different focal lengths based on the actual
installation location of the cameras and the requirements of the Owner.
5. Where interior cameras are mounted to the wall, the Contractor shall provide a mount
that will allow all cables to route through the mount. Cables shall not be “free-floating”
from the wall to the camera.
6. When a camera is pendant mounted the contractor shall install a down-pipe and
conduit support to mount the camera at the correct height as determined by the
owner.
D. Contractor shall focus and aim all cameras
1. After initial camera installation the contractor shall meet with the owner to view each
camera image and understand how that does or does not meet their needs.
2. For cameras that do not provide the correct coverage the contractor shall re-aim the
camera to cover the desired area.
E. Camera naming
1. The contractor shall work with the owner and engineer to determine the naming and
numbering convention for the cameras.
2. Determine the naming and then apply that to each camera. Enter the designation of
the camera into the video security system.
3. On all interior cameras the contractor shall affix a label with the camera number to the
exterior case of the camera. This shall be visible when standing near the camera.
END OF SECTION