2. Some locations require outdoor rated cabling. The contractor shall provide the
cabling to match the required area.
3. There will be requirements for many different types of cabling and the contractor shall
provide for each.
4. Provide a coil of cable at each location for moves and maintenance.
5. Wire from the power supply to Latch retraction devices shall be no smaller than
18AWG.
2.04 TERMS
A. The system shall be fully configurable and compartmentalized so that any user can be
assigned and they will only see the status of doors at one building.
1. Based on a users login, the system shall be configurable to restrict persons from
seeing or controlling doors and lock schedules at building that they do not have
permission to see or control.
2.05 SECURITY SYSTEM (ALL WORK TO BE PROVIDED)
A. Management Server:
1. Contractor shall supply a new server which will be located in the data center. The
servers shall hold all records and database information. The servers shall be
equipped with dual hard drives that are fully mirrored and shall work in hot/failover
mode so that losing one would not impact the use of the security system. The
PC/server shall be shipped new in the manufacturer’s box.
2. Servers shall be located in the data center and shall be a control point for the security
system. The server shall allow no less than 20 separate other operator workstation to
login to control/configure the security system. Access shall be via client software or
via a web interface. The contractor shall install software and configure no less than
10 of the owners PC’s to act as remote control stations.
a. Provide software licenses for no less than 5 complete operator workstations.
3. Server shall have the following components at a minimum:
a. Quad core processor with minimum of 3.1 Ghz or equal.
b. Operating system compatible with security/access system.
c. Dual, mirrored 250 Gigabit hard drives.
d. Read/Write CD-ROM.
e. 8 Gig RAM memory (Expandable..
f. Dual on board 10/100/1000 Ethernet cards.
g. Audio card with speakers.
h. Minimum of a 20 inch LCD monitor.
i. keyboard/monitor/mouse shelf
j. Backup software.
k. Dual Power Supplies
4. Servers shall be capable of handling all software to manage and configure the
security system.
5. Contractor shall connect the Server to the Ethernet in the building.
6. Provide all equipment required to mount the Server in the cabinet/rck
7. Server shall connect to the Network Intelligent controllers via the Ethernet network
8. Provide each server with a Parts Kit.
B. The security system shall utilize a commercially available, Open DataBase Connectivity-
compliant (ODBC) SQL open architecture relational database.
1. The software shall allow flexibility in design allowing the integration into other data
structures.
2. This database shall handle the storage and retrieval of all card holder records
information, images, system maps, reports, and screen designs.
3. The database shall operate in a truly multitasking environment without degradation of
system operation and be of a design that will handle the transaction loading placed
on the system.