Specifications

Technology Upgrade Access Control 28 3500-2
1224_01
2. UL 294 Access Control Systems
3. UL 1076 Line Supervision
4. 21 CFR part 11
5. Part 15, Radio Frequency Devices
6. National Electrical Manufacturers Association (NEMA.
7. Applicable Federal, State and Local laws, regulations, codes
8. Americans with Disabilities Act (ADA.
9. National Electrical Code (NEC.
PART 2 - PRODUCTS
2.01 MANUFACTURERS
A. Approved vendors for security cables are:
1. General Cable.
2. Belden.
3. West Penn Wire and Cable.
4. Equivalent manufacturers.
B. Approved vendor for access control/intrusion detection equipment is:
1. Lenel
2. Open Options
3. RS2
4. Other manufacturers as approved PRIOR TO BID. Submit pre-bid RFI requests for
other products.
a. Systems submitted as part of the base bid that were not pre-approved in
writing during bidding will not be reviewed.
C. As part of the bid the contractor shall explicitly detail the software package that is provided
and shall provide a document showing all software available from the manufacturer.
1. The document shall explicitly state which software is provided as part of the bid and
shall detail other software available but not provided as part of the bid.
2. We require this to be able to determine the level of software available and will allow
us to fully review the system as a whole.
2.02 DESCRIPTION OF PROJECT
A. The access control system shall be an all-encompassing system that is large enough to
serve up to 400 employees, collect data and monitor doors and entrances at no less than 3
different buildings.
B. The system shall include all equipment, software, cabling, data collection points, raceways,
card readers and hardware to monitor and control the specified buildings and provide reports
to a security station in the office of each building.
C. The access control and intrusion detection system shall act as one system. They shall be
integrated such that the presentation of a known access card will shunt all intrusion alarms
for the door where the card was presented.
D. The system shall keep records of all access control card presentations.
E. The system shall connect to and interoperate with all the door hardware that which is
existing.
F. The system shall be able to be connected to other buildings via the existing data network.
Specify how the system will connect to other buildings as part of your bid response.
G. The Owner shall be able to change and monitor all settings for intrusion and access to all the
buildings through the control PC.
2.03 CABLES
A. All security and control cables shall be plenum rated.
1. Contractor shall provide all appropriate cable from the door security hardware to the
security system panels and power supplies. All cabling shall be plenum rated.