Specifications
Technology Upgrade Labeling 28 7600-5
1224_01
The YY represents the cables number in that panel 01-48.
DDD = the camera number within that building
a. The cable label shall be similar to the label below:
A-X-YY-DDD
A-X-YY-DDD
A-X-YY-DDD
b. Provide a sample label to the Engineer for approval prior to installation of all
labels.
A = Communications room
BB = Patch panel where cable terminates
CC = Port on patch panel where cable terminates
DDD = Camera number
H. All labels shall be installed to more easily identify the cables and ports on all panels. If there
are any questions regarding labeling, contact the Engineer prior to installation.
I. Access Control cables shall be labeled.
1. The cables at the door devices shall be labeled where they connect to the device at
the door
2. The cables at the panels in the communications rooms shall be labeled with the door
number
3. Cable labels shall be installed within 3 inches of the end of the cable sheath.
a. The cable label shall be similar to the label below:
125A-DC
125A-DC
125A-DC
b. Provide a sample label to the Engineer for approval prior to installation of all
labels.
125A-DC
The 125A stands for the Door Number.
The DC stands for Door Contact. This could be any of the field devices:
RX,ES, EL, MX, KP etc.
J. Ethernet switch label shall look like the following:
1. Adhere to the front/back or top of each switch. Label location shall be consistent
throughout the network.