Technical data
THE RELEVANT BRITISH STANDARDS MUST BE FOLLOWED 
BS 5871 :PART 3 
BS 5440: PART 1 AND 2 
BS 6891 
BS 8303 
BS 1251 
AND I.S 813 FOR IRELAND 
A BRICK CHAMBER TO THE SIZES IN FIG 2 IN AN EXISTING BRICK OR 
STONE CHIMNEY A 125mm MINIMUM DIAMETER FLUE LINER 
CONFORMING TO BS715 MAY BE USED, PROVIDING IT IS SEALED AT 
THE TOP AND BOTTOM OF THE EXISTING BRICK OR STONE CHIMNEY. 
NOTE 
ANY OF THE ABOVE FLUES MUST NOT BE RESTRICTED BY DAMPERS OR 
REGISTER PLATES, THE FLUE MUST SERVE ONLY ONE APPLIANCE AND 
NOT HAVE ANY BRANCHES OR TRAPS WHICH MAY IMPEDE THE 
NATURAL DRAUGHT .IF ANY TERMINAL IS FITTED IT MUST BE 
SUITABLE FOR THE PURPOSE. 
300mm
765mm
50mm
FIG 3 
AS FOR FIG 2 
THE FRONT FACE SEAL MUST BE FLAT TO ENSURE A GOOD SEAL IS 
FORMED BETWEEN THE REAR AND BASE OF THE APPLIANCE AND 
CHIMNEY TO AVOID ANY REDUCTION IN THE NATURAL DRAUGHT. 
ALWAYS ENSURE THE HEARTH IS LEVELED OFF TO HELP ENSURE 
NO NATURAL DRAUGHT IS LOST BELOW BASE (SEE FIG 3) 
ISSUE 2 
6