Technical data
WARNING 
THIS APPLIANCE HAS A NAKED FLAME, AS WITH ALL SUCH FIRES IT 
IS RECOMMENDED THAT A FIREGUARD SHOULD BE USED FOR THE 
PROTECTION OF CHILDREN, THE ELDERLY AND INFIRM. FIRE 
GUARDS SHOULD CONFORM TO BS8423 2002 (FIREGUARDS FOR FIRES 
AND HEATING APPLIANCES FOR DOMESTIC USE-SPECIFICATION) 
INSTALLATION REQUIREMENTS 
PRE CAST FLUES 
A PRECAST FLUE CONFORMING TO THE REQUIREMENTS OF BS 1289 
PART 1.FOR DETAILS OF THE DIMENSIONS REQUIRED TO LOCATE 
POSITION OF THE APPLIANCE WITHIN THE OPENING/STARTER BLOCKS 
SEE FIG 1. 
WITH A MINIMUM 3 METERS EFFECTIVE HEIGHT. 
400mm
560mm
200mm
300mm
765mm
50mm
FIG 1 
NOTE 
AN INSPECTION SHOULD BE MADE TO ENSURE THAT THE INTERNAL 
WALLS OF THE FLUE ARE CLEAR OF MORTAR FANGS PRIOR TO 
INSTALLING THE APPLIANCE. 
A 50mm SPACER CAN BE FITTED TO ALLOW MORE DEPTH IF REQUIRED 
USING THE FOLLOWING PROCEDURE. 
MARK POSITION OF FLANGE HOLES, DRILL AND PLUG AND FIX SPACER 
USING FOAM SEAL SUPPLIED. THEN SCREW FIRE TO SPACER SEALING 
WITH FOAM SEAL SUPPLIED AND SCREWS SUPPLIED WITH SPACER. 